Chapter 3 Initial Configuration
Configuring CPU Switch Module Redundancy
Configuring Privileged EXEC Mode Access on the Standby CPU Switch Module
Access to privileged EXEC mode from the standby CPU switch module CLI can be enabled from the active CPU switch module CLI. This feature provides extra security for the Cisco ONS 15530 system.
To configure access to privileged EXEC mode on the standby CPU switch module, perform the following steps on the active CPU switch module CLI, beginning in global configuration mode:
| Command | Purpose |
Step 1 |
|
|
Switch(config)# redundancy | Enters redundancy configuration mode. | |
|
| |
Step 2 |
|
|
| Enables access to privileged EXEC mode from the | |
| enable | standby CPU switch module CLI. The default state |
|
| is disabled. |
|
|
|
Example
The following example shows how to configure redundancy maintenance mode:
Switch(config)# redundancy
Displaying the Standby CPU Switch Module Privileged EXEC Mode Status
To display the privileged EXEC mode access status on the standby CPU switch module, use the following privileged EXEC command:
Command | Purpose |
|
|
show redundancy summary | Displays the redundancy configuration and status. |
|
|
| Cisco ONS 15530 Configuration Guide and Command Reference |