Cisco Systems 6500, 7600 manual Vertical slots

Page 9

Installing the WiSM

Vertical slots

a.Position the supervisor engine or switching module in the slot. (See Figure 5.) Make sure that you align the sides of the switching-module carrier with the slot guides on the top and bottom of the slot.

b.Carefully slide the WiSM into the slot until the EMI gasket along the right edge of the module makes contact with the module in the slot adjacent to it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate. (See Figure 6.)

c.Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure to the left, deflecting the module approximately 0.04 inches (1 mm) to create a small gap between the module’s EMI gasket and the module adjacent to it. (See Figure 6.)

Caution Do not exert too much pressure on the ejector levers. They will bend and be damaged.

d.While pressing on the ejector levers, simultaneously close them to fully seat the WiSM in the backplane connector. The ejector levers are fully closed when they are flush with the module faceplate. (See Figure 7.)

e.Tighten the two captive installation screws on the module.

Note Make sure that the ejector levers are fully closed before tightening the captive installation screws.

f.Verify that the WiSM STATUS LED is lit. Check the STATUS LED periodically. If the STATUS LED changes from orange to green, the WiSM has successfully completed the boot process and is now online. If the STATUS LED remains orange or turns red, the WiSM has not successfully completed the boot process and may have encountered an error.

Catalyst 6500 Series Switch and Cisco 7600 Series Router Wireless Services Module Installation and Verification Note

 

78-17121-04

9

 

 

 

Image 9
Contents Contents Front Panel Description LEDsColor/Description System Requirements Power RequirementsConsole Ports Hardware ComponentsSafety Overview Required ToolsSoftware Requirements Installing the WiSM See Figure Horizontal slotsPositioning the Module in a Horizontal Slot Chassis Clearing the EMI Gasket in a Horizontal Slot Chassis Vertical slots Positioning the Module in a Vertical Slot Chassis Clearing the EMI Gasket in a Vertical Slot Chassis Verifying the Installation Verifying the InstallationRemoving the WiSM Configuring the WiSMRelated Documentation Regulatory Standards ComplianceObtaining Documentation Cisco.comCisco Product Security Overview Documentation FeedbackProduct Documentation DVD Ordering DocumentationObtaining Technical Assistance Reporting Security Problems in Cisco ProductsCisco Technical Support & Documentation Website Submitting a Service RequestObtaining Additional Publications and Information Definitions of Service Request SeverityObtaining Additional Publications and Information Obtaining Additional Publications and Information