Cisco Systems PA-4T manual Placing the Port Adapter Lever in the Locked Position-Cisco

Page 40

Installing a Port Adapter

Step 5 With the port adapter halfway in the slot, connect all required cables to the port adapter.

Step 6 After connecting all required cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the router midplane.

Step 7 After seating the port adapter in the router midplane, move the port adapter lever to the locked position. Figure 4-5 shows the port adapter lever in the locked position.

Note If the port adapter lever does not move to the locked position, the port adapter is not completely seated in the midplane. Carefully pull the port adapter halfway out of the slot, reinsert it, and move the port adapter lever to the locked position.

Figure 4-5 Placing the Port Adapter Lever in the Locked Position—Cisco 7206

 

 

 

 

 

 

 

 

 

 

 

6

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ETHERNET 10BT

 

 

FAST ETHERNET

 

 

 

 

 

 

 

 

ENABLED

 

LINK RJ45

 

 

 

 

 

 

 

 

 

MII

 

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

FAST SERIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLOT

1

FE

MII

 

FAST ETHERNET INPUT/OUTPUT CONTROLLER

 

H6747

 

 

 

 

 

 

 

 

0

ENABLED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCMCIA

EJECT

SLOT

0

 

 

MII

RJ45

RJ45

 

 

 

 

 

 

 

 

 

 

EN

EN

LINK

 

 

 

 

 

 

 

 

 

 

Port adapter

 

 

 

 

 

 

 

 

 

 

handle

 

 

 

Note: This adapter installation applies to any port or service adapter.

Port adapter lever (locked position)

This completes the procedure for installing a new port adapter in a Cisco 7200 series router. Proceed to Chapter 7, “Installing the PA-4T+ Interface Cables,” to connect the necessary cables to your port adapter.

4-4PA-4T+ Synchronous Serial Port Adapter Installation and Configuration

Image 40
Contents Corporate Headquarters Copyright 1997-1999 Cisco Systems, Inc All rights reserved Overview Port Adapter OverviewPA-4T Port Adapter-Faceplate View Synchronous Serial Overview Router# show diagSerial Interface Specifications Cables and Pinouts PA-4T+ Receptacles and CablesSerial Port Adapter Cables EIA/TIA-232 Connections EIA/TIA-449 Connections PA-4T+ Port Adapter Cable Pinouts EIA-530 ConnectionsRTS/CTS CTS/RTS DSR/DTR DTR/DSR RTS CTS DSR SD+ Shield ground RTS/CTS CTS/RTS DSR/DTR DTR/DSR DCD/LL Rlsd LL/DCD LEDs LEDs on the PA-4T+-Horizontal OrientationLEDs Preface ObjectivesDocument Organization Related DocumentationCisco Connection Online Documentation CD-ROM Preparing for Installation Tools and Parts RequiredSoftware and Hardware Requirements Router Platform Recommended Minimum Cisco IOS ReleaseSoftware and Hardware Requirements Safety Guidelines Safety WarningsTelephone Wiring Guidelines Electrical Equipment GuidelinesFCC Class B Compliance Preventing Electrostatic Discharge DamageFCC Class B Compliance FCC Class B Compliance Installation Overview VIP2 and the PA-4T+ Port AdapterVIP2-15 or VIP2-40 with a PA-4T+ in Port Adapter Slot Removing a Port Adapter Installing a Port Adapter Location of Port Adapter Screw-Partial Port Adapter ViewAligning a Port Adapter in a Port Adapter Slot H3152 Cisco 7206 with a PA-4T+ Installed Cisco 7200 Series PA-4T+ Port AdapterPort adapter Handle Lever unlocked Position Handling a Port Adapter Placing the Port Adapter Lever in the Locked Position-Cisco Cisco uBR7200 Series and the PA-4T+ Port Adapter Port adapters Port adapters Port adapter lever in unlocked position Inside slot guide PC board Metal carrier Placing the Port Adapter Lever in the Locked Position Installing a Port Adapter Cisco 7100 Series PA-4T+ Port Adapter Cisco 7120 Series Router-Port Adapter Slot 3 LocationCisco 7140 Series Router-Port Adapter Slot 4 Location Installing a Port Adapter Guides Installing the PA-4T+ Interface Cables Attaching PA-4T+ Port Adapter Interface CablesReplacing PA-4T+ Port Adapter Cables Incorrect, cable upside downFor a VIP2, use the following commands Router# copy running-config startup-config Configuring the PA-4T+ Interfaces Using the Exec Command InterpreterCisco 7200 Series and Cisco uBR7200 Series Ports PA-4T+ Interface Port Address Example-Cisco uBR7246 VIP2 Ports PA-4T+ Interface Port Address Example-CiscoShutting Down an Interface Cisco 7100 Series PortsEnter the shutdown command as follows Router# show interfaces serial 1/0 Performing a Basic Configuration Configure additional interfaces as requiredConfiguring Timing Clock Signals Setting the Clock RateInverting the Clock Signal Inverting the Data Signal Configuring Half-Duplex and Binary Synchronous Communications Configuring Half-Duplex Checking the Configuration Using show Commands to Verify the New Interface StatusConfiguring Bisync Using show Commands to Display Interface Information Hardware is M4T Internet address isChecking the Configuration Router# show version VIP2 show interfaces Command Minute output rate 0 bits/sec, 0 packets/sec System image file is image-name, booted via tftp from Using ping and loopback Commands Checking the Configuration