Cisco Systems PA-4T manual Shutting Down an Interface, Cisco 7100 Series Ports

Page 59

Cisco 7100 Series Ports

Cisco 7100 Series Ports

In Cisco 7100 series routers, the slot number is the location in the chassis where the interface resides and the port number is the physical port. Interfaces in the Cisco IOS software are identified by a type, slot number, and port number. For example, serial 3/1 indicates port 1 on the serial port adapter in slot 3.

Slots in Cisco 7120 series routers are numbered as shown in Figure 8-4. The fixed LAN interface is slot 0, the fixed WAN interface is slot 1, and the modular port adapter interface is slot 3. On the Cisco 7120 series, slots 2 and 4 are not used. Slot 5 is the service adapter.

Figure 8-4 Port Adapter Slot Numbering—Cisco 7120 Series

Slot 5

Slot 3

ACT ACT

5

 

 

LNK

LNK

 

 

 

FE 0 / 0 FE 0 / 1 0

1

I

 

E3 TX

RX

 

EN

RX

 

 

 

 

CEL CAR ALM

 

 

SLOT 0

SLOT 1

 

PWR

 

0

 

SYS

CONS

AUX RDY

 

2

7120 - AE3

18498

Slot 1

Slot 0

Slots in the Cisco 7140 series are numbered as shown Figure 8-5. The fixed LAN interface is slot 0, the fixed WAN interfaces are slots 1 and 2, and the modular port adapter interface is slot 4. Slot 3 is not used. Slot 5 is the service adapter.

Figure 8-5 Port Adapter Slot Numbering—Cisco 7140 Series

Slot 5

Slot 4

BOOT

SM-EC-DS

RESET ERROR

5 EN

IRX 155 - MM TX

ENRX

CEL CAR ALM

SLOT 0

SLOT 1

 

 

 

 

 

 

 

 

 

ACT

ACT

 

 

 

 

 

 

 

 

 

 

LNK

LNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

 

FE 0 / 0 FE 0 / 1

 

155 - MM

 

 

 

 

 

 

 

 

 

 

RX TX

EN

RX

CEL CAR ALM

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

SYS

 

 

 

 

 

 

 

 

 

CONS

 

 

 

AUX

RDY

7140 - 2MM3

 

AC OK

 

 

DC OK

 

 

OTF

 

0

 

 

 

AC OK

 

 

DC OK

 

 

OTF

18499

2

 

 

 

Slot 1

Slot 0 Slot 2

Shutting Down an Interface

Before you replace an interface cable, replace port adapters, or remove an interface that you will not replace, use the shutdown command to shut down (disable) the interfaces. Doing so prevents anomalies from occurring when you reinstall the new or reconfigured port adapter. When you shut down an interface, it is designated administratively down in the show command displays.

Follow these steps to shut down an interface:

Step 1 Enter the privileged level of the EXEC command interpreter. (See the “Using the EXEC Command Interpreter” section on page 8-1 for instructions.)

Configuring the PA-4T+ Interfaces 8-5

Image 59
Contents Corporate Headquarters Copyright 1997-1999 Cisco Systems, Inc All rights reserved Port Adapter Overview OverviewPA-4T Port Adapter-Faceplate View Router# show diag Synchronous Serial OverviewSerial Interface Specifications PA-4T+ Receptacles and Cables Cables and PinoutsSerial Port Adapter Cables EIA/TIA-232 Connections EIA/TIA-449 Connections EIA-530 Connections PA-4T+ Port Adapter Cable PinoutsRTS/CTS CTS/RTS DSR/DTR DTR/DSR RTS CTS DSR SD+ Shield ground RTS/CTS CTS/RTS DSR/DTR DTR/DSR DCD/LL Rlsd LL/DCD LEDs on the PA-4T+-Horizontal Orientation LEDsLEDs Objectives PrefaceRelated Documentation Document OrganizationCisco Connection Online Documentation CD-ROM Tools and Parts Required Preparing for InstallationRouter Platform Recommended Minimum Cisco IOS Release Software and Hardware RequirementsSoftware and Hardware Requirements Safety Warnings Safety GuidelinesElectrical Equipment Guidelines Telephone Wiring GuidelinesPreventing Electrostatic Discharge Damage FCC Class B ComplianceFCC Class B Compliance FCC Class B Compliance VIP2 and the PA-4T+ Port Adapter Installation OverviewVIP2-15 or VIP2-40 with a PA-4T+ in Port Adapter Slot Removing a Port Adapter Location of Port Adapter Screw-Partial Port Adapter View Installing a Port AdapterAligning a Port Adapter in a Port Adapter Slot H3152 Cisco 7200 Series PA-4T+ Port Adapter Cisco 7206 with a PA-4T+ InstalledPort adapter Handle Lever unlocked Position Handling a Port Adapter Placing the Port Adapter Lever in the Locked Position-Cisco Cisco uBR7200 Series and the PA-4T+ Port Adapter Port adapters Port adapters Port adapter lever in unlocked position Inside slot guide PC board Metal carrier Placing the Port Adapter Lever in the Locked Position Installing a Port Adapter Cisco 7120 Series Router-Port Adapter Slot 3 Location Cisco 7100 Series PA-4T+ Port AdapterCisco 7140 Series Router-Port Adapter Slot 4 Location Installing a Port Adapter Guides Attaching PA-4T+ Port Adapter Interface Cables Installing the PA-4T+ Interface CablesIncorrect, cable upside down Replacing PA-4T+ Port Adapter CablesFor a VIP2, use the following commands Router# copy running-config startup-config Using the Exec Command Interpreter Configuring the PA-4T+ InterfacesCisco 7200 Series and Cisco uBR7200 Series Ports PA-4T+ Interface Port Address Example-Cisco uBR7246 PA-4T+ Interface Port Address Example-Cisco VIP2 PortsCisco 7100 Series Ports Shutting Down an InterfaceEnter the shutdown command as follows Router# show interfaces serial 1/0 Configure additional interfaces as required Performing a Basic ConfigurationSetting the Clock Rate Configuring Timing Clock SignalsInverting the Clock Signal Inverting the Data Signal Configuring Half-Duplex and Binary Synchronous Communications Configuring Half-Duplex Configuring Bisync Using show Commands to Verify the New Interface StatusChecking the Configuration Hardware is M4T Internet address is Using show Commands to Display Interface InformationChecking the Configuration Router# show version VIP2 show interfaces Command Minute output rate 0 bits/sec, 0 packets/sec System image file is image-name, booted via tftp from Using ping and loopback Commands Checking the Configuration