Prerequisites and Preparation
Required Tools and Equipment
Table 1 lists the tools and equipment you need to install a DC PEM.
Table 1 | Tools and Equipment |
|
|
|
|
|
| ||
Quantity | Description | Comments | ||
|
|
| ||
1 | Antistatic wrist or ankle strap | Prevents damage to equipment | ||
| with connection cord | from electrostatic discharge | ||
|
| (ESD). |
| |
|
|
|
|
|
1 | Number 2 phillips screwdriver |
|
| — |
|
|
| ||
1 | Blade should measure 1.0 mm | |||
| recommend a | thick by 4.0 mm wide. An | ||
| screwdriver. | appropriate screwdriver is | ||
|
| available from Phoenix Contact | ||
|
| Inc. of Harrisburg, PA, USA. | ||
|
|
| ||
1 | Wire stripping tool | Choose a tool that does not nick | ||
|
| the internal wire. | ||
|
|
|
|
|
2 or 4 | Tie wraps |
|
| — |
|
|
|
|
|
1 | Metric measuring tape or ruler |
|
| — |
|
|
|
|
|
1 | Marking pen |
|
| — |
|
|
|
|
|
1 | Voltmeter |
|
| — |
|
|
| ||
3 or 6 | 6 AWG (recommended) copper | The wires must meet these | ||
(length | wires long enough to reach from | specifications: | ||
varies) | the Cisco 10005 chassis to the | • Conductor size 6 AWG or | ||
| DC power source. | |||
|
| 8 AWG (6 AWG preferred) | ||
|
|
| ||
| • Three wires (two power, one | • | Diameter: | |
| ground) are needed for a | |||
|
| – | Minimum: 3.38 mm | |
| single DC power source. |
| ||
| • Six wires (four power, two |
| – | Maximum: 4.52 mm |
| ground) are needed for two | • | Multistranded copper | |
| DC power sources. | |||
|
| construction | ||
|
|
| ||
|
|
|
|
|
Cisco 10005 ESR DC Power Entry Module Installation