Adding or Replacing a DC PEM

Troubleshooting the Installation

Table 2 provides information you can use to solve problems with a DC PEM.

Table 2 Troubleshooting the DC PEM

Symptom

Steps to Take

 

 

System fails to power

Check that:

on

All power leads are connected to the Cisco 10005

 

 

and to a power source.

 

The power switches are in the (On) position.

 

The Power LED on the PEM is on (green).

 

The fan assembly is fully inserted (Fan Status

 

LED is green).

 

 

Power problems

If the yellow Fault LED on the power module

 

is on:

 

Make sure the power switch on the power

 

module is set to (On).

 

Make sure the power and ground wires are

 

properly connected to the terminals on the

 

PEM. Follow the wiring instructions

 

carefully to ensure that you insert the wires

 

into the correct openings in the terminal

 

block. See the “Wiring a DC PEM” section

 

on page 12 for details.

 

If the Miswire LED on the DC PEM is on, the

 

–48V and return (RTN) wires are reversed. Power

 

off the PEM, turn off the branch circuit that feeds

 

power to the Cisco 10005, and reconnect the

 

wires correctly. (See the “Wiring a DC PEM”

 

section on page 12 for details.)

 

For more troubleshooting information, see the

 

Cisco 10000 Series ESR Troubleshooting Guide.

 

 

 

 

Cisco 10005 ESR DC Power Entry Module Installation

 

 

 

 

 

 

78-12653-01

 

 

19

 

 

 

Image 19
Contents Contents Cisco 10005 ESR DC Power Entry Module InstallationPrerequisites and Preparation Product DescriptionSafety Warnings Safety GuidelinesPrerequisites and Preparation Prerequisites and Preparation Prerequisites and Preparation Quantity Description Comments Required Tools and EquipmentAdding or Replacing a DC PEM Installing a Second DC PEMInserting a DC PEM Replacing a DC PEMCisco 10005 ESR DC Power Entry Module Installation Removing and Replacing a DC PEM Preparing to Connect Power and Ground Wiring a DC PEMConnecting DC Ground Positioning the Power and Ground Terminals to Accept Wires Pull on the wire to ensure that it is held firmly in place Connecting DC Power Connecting Power to the Terminal Block Checking the DC Power Connection Symptom Steps to Take Troubleshooting the InstallationFCC Class B Compliance Manuals for All Cisco 10000 Series Routers Related DocumentationOrdering Documentation Obtaining DocumentationWorld Wide Web Documentation CD-ROMDocumentation Feedback Obtaining Technical AssistanceCisco.com Contacting TAC by Using the Cisco TAC WebsiteTechnical Assistance Center Contacting TAC by Telephone Obtaining Technical Assistance