Cisco Systems AS5350XM manual Preventing Electrostatic Discharge Damage

Page 2

Chapter 2 Preparing to Install the Cisco AS5350XM Universal Gateway

Safety Recommendations

Locate the emergency power-OFF switch for the room in which you are working. Then, if an electrical accident occurs, you can act quickly to turn OFF the power.

Before working on the system, unplug the power cord.

Disconnect all power before doing the following:

Installing or removing a chassis

Working near power supplies

Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046

Never assume that power is disconnected from a circuit. Always check.

Warning Read the installation instructions before connecting the system to the power source. Statement 1004

Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, frayed power cords, and missing safety grounds.

If an electrical accident occurs, proceed as follows:

Use caution; do not become a victim yourself.

Turn OFF power to the system.

If possible, send another person to get medical aid. Otherwise, assess the condition of the victim and then call for help.

Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.

Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors). Statement 13

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures.

Always follow ESD-prevention procedures when you remove and replace components. Ensure that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the grounding clip to an unpainted surface of the chassis frame to safely ground unwanted ESD voltages. To guard against ESD damage and shocks, the wrist strap and cord must operate properly. If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Caution For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohm (Mohm).

Cisco AS5350XM Universal Gateway Chassis Installation Guide

2-2

OL-6417-02

 

 

Image 2
Contents Safety Recommendations Maintaining Safety with ElectricityPreventing Electrostatic Discharge Damage Required Tools and Equipment Preparing to Connect to a NetworkConsole Port Ethernet ConnectionsConsole and Auxiliary Ports Bits Port Alarm Port2T Serial Ports Auxiliary PortPower Supply Considerations