Electrical Requirements For Your Air Conditioner

Electrical Requirements For Your Air Conditioner

BELOW ARE ELECTRICAL PLUG

VARIATIONS. CHOOSE THE ONE WHICH

MATCHES THE AMPERE RATING OF YOUR UNIT. THE NUMBER OF AMPERES IS PRINTED ON THE SERIAL LABEL, ATTACHED TO THE FRONT OF THE UNIT, BEHIND THE FRONT PANEL (SEE PAGE 2).

Chart-A

An REQUIREMENTSELECTRICAL

For 115 volt models with serial plate amperes up through 7.5.

OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES

Do not, under any circumstances, remove the power supply cord ground prong.

RECEPTACLE WIRING

SPRONG

GROUNDING PLUG

I

3. PRONG GROUNDING TYPE WALL RECEPTACLE

POWER SUPPLY CORD

An

For 115 volt models with serial plate amperes up through 7.5

For 230 volt and 23Ol208 volt models with serial plate amperes up through

RECEPTACLE WIRING should be at least as large as 14 gauge. Use copper wire only. It is the

personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri-

cian. OBSERVE NATIONAL ELECTRICAL

CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.

Electrical Requirements

A 115 volt (103.5 min., 126.5 max.) 60 hertz AC only, 15 ampere fused electrical supply is re- quired (time delay fuse or time delay circuit breaker required.). It is recommended that a separate circuit, serving only this appliance, be provided. Do not use and extension cord.

Electrical Connection

Electrical Ground is Required on this Appliance

RECOMMENDED GROUNDING METHOD

RECEPTACLE

For 230 volt and 2301206 volt models with serial plate amperes up through 16.0

For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician. See Figure 1 on page 4.