Electrical Requirements For Your Air Conditioner
BELOW ARE ELECTRICAL PLUG
VARIATIONS. CHOOSE THE ONE WHICH
MATCHES THE AMPERE RATING OF YOUR UNIT. THE NUMBER OF AMPERES IS PRINTED ON THE SERIAL LABEL, ATTACHED TO THE FRONT OF THE UNIT, BEHIND THE FRONT PANEL (SEE PAGE 2).
Chart-A
An REQUIREMENTSELECTRICAL
For 115 volt models with serial plate amperes up through 7.5.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES
Do not, under any circumstances, remove the power supply cord ground prong.
RECEPTACLE WIRING
SPRONG
GROUNDING PLUG
I
3. PRONG GROUNDING TYPE WALL RECEPTACLE
POWER SUPPLY CORD
An
For 115 volt models with serial plate amperes up through 7.5
For 230 volt and 23Ol208 volt models with serial plate amperes up through
RECEPTACLE WIRING should be at least as large as 14 gauge. Use copper wire only. It is the
personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri-
cian. OBSERVE NATIONAL ELECTRICAL
CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.
Electrical Requirements
A 115 volt (103.5 min., 126.5 max.) 60 hertz AC only, 15 ampere fused electrical supply is re- quired (time delay fuse or time delay circuit breaker required.). It is recommended that a separate circuit, serving only this appliance, be provided. Do not use and extension cord.
Electrical Connection
Electrical Ground is Required on this Appliance
RECOMMENDED GROUNDING METHOD
RECEPTACLE
For 230 volt and 2301206 volt models with serial plate amperes up through 16.0
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a