Figure 1
I I
1.I a I
ALTERNATE GROUNDING METHOD
If changing and properly grounding the wall receptacle is impossible and where local codes permit (consult your electrical inspector), a temporary adapter may be plugged into the existing
HOWEVER, IS NOT RECOMMENDED.
If this is done, you must connect the grounded eyelet on the adapter to the wall receptacle cover plate screw and from this same screw, you must connect a separate copper ground wire (#I4 minimum) to a grounded cold water pipe.* See Figure 2. Do not ground to a gas supply pipe. Do not connect to electrical supply until appliance is permanently grounded.
Figure 2
|
|
| GROUND | ASSEMBLY |
(\, | t | ,(““A;;;? | ;;;;NDED | |
|
|
|
| |
|
| 3 | WATEi Pi@ | |
|
|
| COVER | PLATE |
RECEPTACLE
“.,““..“,w3GROUND PRONG
PLUG
POWER SUPPLY CORD
*Cold water pipe must have metal continuity to
electrical ground and not be interrupted by plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a jumper wire at these con- nections.
.
ELECTRICAL
REQUIREMENTS
For 230 volt and 230/208 volt models with serial plate amperes up through 12.0
Refer to Chart B for specific wiring and recep- tacle information to be used.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
Do not, under any circumstances, remove the power supply cord ground plug.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
A
A separate electrical supply is required on a separately fused circuit. Do not fuse ground- neutral.
See Chart B for receptacle voltage requirements, proper fuse size, wire and wiring connections which must conform with rating of the appliance. Do not use an extension cord.
Chart-B
|
|
| RECEPTACLE |
| |
PLUG | AND | VOLTAGE |
| ||
RECEPTACLE | (6Q HERTZ | SERIAL PLATE | |||
DATA |
| AC IN ALL | AMPERES | ||
|
|
| INSTANCES) |
| |
| RECEPTACLE | MODEL | WITH |
| |
|
|
| SERIAL | PLATE |
|
SMALL |
|
| OF 230 | VOLTS |
|
TANDEM |
| ;; | (207 MIN,253 | up | |
BLADES |
| . | MAX.) | ||
| n | lhrou9h | |||
| r |
|
| ||
|
| cil | MODEL | WITH | 12.0 |
l/4" |
| eGROUN0 |
| ||
| SERIAL | PLATE |
| ||
BLADE’ |
| PRONG |
| ||
|
|
| OF 230/209 |
| |
?I |
|
| VOLTS |
| |
a |
|
| (197.6 | MIN. |
|
J |
|
| 253 MAX,) |
| |
USE | MINIMUM |
| |||
FUSE |
|
| |||
| RECEPTACLE | TYPE | |||
OR TIME | |||||
DELAY | CIRCUIT | WIRE | SUE | OF BRANCH | |
BREAKER |
|
| CIRCUIT | ||
RATING | IN | SEE SELOW |
| ||
AMPS |
|
|
|
| |
| @ |
| 14 GAUGE | SINGLE | |
|
|
|
| OUTLET | |
Go |
|
| USE COPPER | ||
|
| ONLY | |||
15 |
| WIRE | ONLY |
| |
|
|
|
|