ST-3050D SUB. PUMP/CONTRL. BOX — WIRING DIAGRAM (CB200)

EXTERNAL 3-PHASE (230 OR 460 VOLT)

POWER SOURCE

CIRCUIT

BREAKER

L1RED WHITE

L2BLACK

L3

GREEN

 

GROUND

THREE PHASE WIRING

ELECTRONIC

CONNECTIONSOVERLOAD UNIT

TERMINALS

 

 

 

 

 

M

O/L

 

 

L1

 

 

 

 

1

2

T1

 

 

 

 

 

 

 

 

L2

 

 

 

 

3

4

T2

PUMP

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

5

6

T3

 

L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1

H3

H2

H4

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

TRANSFORMER

SEE FIGURE 1 FOR JUMPER SELECTION

 

F1

 

 

 

50VA CPT

230 0R 460 VAC SELECTION.

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

XF

FUSE

X1

 

 

X2

 

 

 

 

 

 

 

 

 

 

 

1/2 AMP

 

 

 

 

 

 

 

OFF

MANUAL

5

11

23

WARNING

ONLY A LICENSED ELECTRICIAN OR QUALIFIED PERSONNEL SHOULD PERFORM WIRING AND I N S T A L L A T I O N O F T H I S CONTROL PANEL.

AUTO

1

12

4

24

3

1

14 13

4 3 2

ON

INDICATOR

LAMP

1G 7

 

CONTACTOR

 

 

 

 

 

5 HP

 

 

O/L

 

1

M

7

 

 

6

 

A1

A2

96

95

 

 

TERMINAL

 

 

 

 

 

BLOCK

NOTE:

 

 

 

 

 

 

 

 

 

 

1. REFER TO PAGE 20 OF THIS MANUAL

 

 

1

 

 

FOR THE CORRECT SETTING OF THE

 

 

ELECTRONIC OVERLOAD UNIT.

 

 

 

STOPSTART

FLOATFLOAT

SWITCHSWITCH

Figure 7. Control Box Wiring Diagram

Float switch connections are for

NOTE use with the CB200 Control Box only!

ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 17

Page 17
Image 17
Multiquip manual ST-3050D SUB. PUMP/CONTRL. BOX Wiring Diagram CB200, Control Box Wiring Diagram