ST-3050D SUBMERSIBLE PUMP/CTRL. BOX — PRE SETUP (CB200)

ELECTRONIC OVERLOAD UNIT SETTINGS

ElectronicOverloadUnit:Alwaysmakesurethat theelectronicunitsuppliedwiththecontrolboxisset to the correct amperage.This overload unit must MATCH the amperage requirements of the pump motor.

Using an electronic overload unit with incorrect settings may result in serious damage to the pump. Refer to the Pump Amperage Requirements Table (Table 7), for the correct overload amperage settings.

There are two dials on the Electronic Overload Unit (Figure 9) that require adjustment to meet the amperage requirement of the pump motor in use.

These dials are located on top of the overload unit and are labeled CLASS and FLC (A).

Use a phillips-head screw driver to adjust the dials to the correct settings.

FLC (A) Dial Setting

1.Set the FLC (A) dial pointer (Figure 9) to the correct amperage for the pump motor in use. Use Table 7, to determine the correct amperage setting.

ClassDialSetting

1.Set the CLASS dial pointer (Figure 9) to the HAND position 10. This controls the reset function only. It does not affect the ability of the pump to run with or without float switches.

RESETOperation

This electronic control unit has two modes of reset.The modes are defined as follows:

MODE 1

WhentheCLASSdialontheelectronicoverloadmodule isintheHAND position(manual)theresetbutton(Figure10)onthefrontofthecontrol box must be pushed to reset the unit (restore power) in the event of anoverload.

Figure 10. Control Box Reset Button

MODE 1

WhentheCLASSdialontheelectronicoverloadmoduleisintheAUTO position (automatic mode) the unit will automatically be reset in the event of an overload

NOTE

All Multiquip control boxes should have the CLASS dial set to the HAND position 10.

Figure 9. Electronic Overload Module

TABLE 7. PUMP MOTOR AMPERAGE REQUIREMENTSS

Pump Model

Control

Volts

Amps

Overload Unit

Box

(VAC)

 

 

 

 

 

 

 

 

ST3050D

CB200

230

14.2

AXE016-6.40-16A

Three-Phase

 

 

 

 

 

 

 

 

 

ST3050D

CB200

460

7.1

AXE016-6.40-16A

Three-Phase

 

 

 

 

 

 

 

 

 

Operation

1.From the voltage source set the circuit breaker or quick disconnect switch to the ON position.

2.For manual operation of the pump, place the 3-position operation switch (Figure 11) on the control box in the MANUAL position.

Figure 11. Manual-Off-On SW. (Man Position)