ST-3050D SUBMERSIBLE PUMP —TROUBLESHOOTING
TABLE X. PUMP TROUBLESHOOTING
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
|
| Check that proper voltage (230/460 3Ø) is being supplied to the | |
| Incorrect voltage/amps? | pump. Also check that there is an adequate amount of current | |
|
| (amps) to run the pump. Check power source circuit breaker. | |
|
|
| |
| Check electrical connections? | If using float switches check wiring, inspect power cord. | |
|
|
| |
| Blown power fuse? | Replace fuse, check cause of blown fuse. | |
Pump Fails To Start |
|
| |
Impeller locked? | Disconnect power cord and check for clogging and improper impeller | ||
| clearance. Unclog pump. Check overload protection device. | ||
|
| ||
|
|
| |
|
| Use multimeter to check motor insulation. Insulation resistance must | |
| Wet motor windings? | be approximately 15 megaohms. If resistance is low, disassemble | |
|
| pump motor and bake windings to dry them. | |
|
|
| |
| Defective motor and pump | Check for excessive bearing wear, if worn replace bearings. Replace | |
| bearings? | motor if defective. | |
|
|
| |
| Twisted or restricted discharge | Lay hose flat | |
| hose? |
| |
|
|
| |
| Clogged pump strainer? | Clean strainer. | |
Pump Fails to Deliver Full |
|
| |
| Use a voltmeter to check voltage while pump is energized. Voltage | ||
Output |
| ||
Low voltage? | must be within ±10%. Check power source (no load and load). If an | ||
| |||
| extension cord is used, make sure it has adequate | ||
|
| ||
|
| capacity for the required length. | |
|
|
| |
| Impeller worn? | Replace impeller. | |
|
|
| |
Water in Seal Oil | Defective water seal? | Replace water seal. | |
|
| ||
Loose Oil Fill Plug? | Tighten securely. | ||
| |||
|
|
|
Performance Curve
| (Feet) | 90 |
|
|
|
|
| Head |
|
|
|
| |
|
|
|
|
| TOTAL HEAD | |
|
|
|
|
|
| |
| Total |
|
|
|
| Max 86 ft |
|
|
|
|
| CAPACITY | |
|
|
|
|
|
| |
Figure 20. |
| 60 |
|
|
| Max 264 G.P.M |
Performance Chart |
|
|
|
| ||
|
|
|
|
| ||
|
| 30 |
|
|
|
|
|
| 0 | 100 | 200 | 300 | Capacity(US.G.P.M) |
|
|
| ||||
|