Cisco Systems 2800 manual Grounding the Chassis, Installing the Router on a Desktop

Page 17

Caution The router must be mounted with the power connections oriented downward. Failure to do so could present a fire hazard.

Installing the Router on a Desktop

If you install your Cisco 2800 series router on a desktop, observe the following precautions:

Note For Cisco 2801 routers, attach the four rubber feet to the bottom of the chassis.

Caution Your chassis installation must allow unrestricted airflow for chassis cooling. For placing the router on a desktop, keep at least 1 inch (2.54 cm) of clear space beside the cooling inlet and exhaust vents.

Caution Do not place any items that weigh more than 10 pounds (4.5 kilograms) on top of the chassis, and do not stack routers on a desktop.

Grounding the Chassis

Warning

This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of

 

 

a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if

 

 

you are uncertain that suitable grounding is available. Statement 1024

 

 

 

 

 

 

Warning

During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the

 

 

backplane with your hand or any metal tool, or you could shock yourself. Statement 94

 

 

 

Note This equipment is suitable for installation in Network Telecommunications Facilities and locations where the NEC applies. The equipment is suitable for installation as part of the Common Bonding Network (CBN).

You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical safety standards.

For NEBS-compliant grounding, use size 6 AWG (13 mm2) copper wire and the ground lug provided in the accessory kit.

For NEC-compliant grounding, use size 14 AWG (2 mm2) or larger copper wire and an appropriate user-supplied ring terminal with an inner diameter of 1/4 in. (5-7 mm).

For EN/IEC 60950-compliant grounding, use size 18 AWG (1 mm2) or larger copper wire and an appropriate user-supplied ring terminal.

Warning

This equipment needs to be grounded. Use a green and yellow 14 AWG ground wire to connect the host to earth

 

ground during normal use. Statement 190

 

 

To connect the chassis to a reliable earth ground, perform the following steps:

Step 1 Strip one end of the ground wire to the length required for the ground lug or terminal.

For the NEBS ground lug—approximately 0.75 inches (20 mm)

For user-provided ring terminal—as required

17

Image 17
Contents Including License and Warranty Replacement, Repair, or Refund Policy for Hardware Cisco 90-Day Limited Hardware Warranty TermsDuration of Hardware Warranty Overview To Receive a Return Materials Authorization RMA NumberSerial Number Label Location for Cisco 2801 Router Product Serial Number LocationUser Documentation Documents, Equipment, and ToolsItems Included with Cisco 2801 Routers Translated VersionsItems Not Included Install ChassisSafety Information Page OBS! Spara Dessa Anvisningar Guarde Estas Instruções GEM Disse Anvisninger Page Statement Installing the RouterAttaching Brackets to the Router for Rack-Mounting Rack-Mounting the RouterBracket Installation for Front Mounting Installing the Router in a Rack Attaching Brackets to the Router for Wall Mounting Wall-Mounting the Router-Cisco 2811 Routers OnlyGround during normal use. Statement Installing the Router on a DesktopGrounding the Chassis Chassis Ground Connection on Cisco 2801 Chassis Connect Cables Connecting the Router to AC Power Power ConnectionsProtective device is rated not greater than 120 VAC, 15 a 240 VAC, 10 A. StatementSize Wire Terminal Lug Protection Connecting the Router to DC Power60 VDC, 20 A. Statement Use copper conductors only. StatementInsulation and conductor. Statement TipStep Be connected first and disconnected last. StatementElectrical hazards. Statement DC Wire Routing and Attachment for Cisco 2811 RoutersConnecting to One Source Only-Source a or Source B Source a and Source B Wired with Opposite-Polarity Grounds WAN, LAN, and Voice Connections Connecting the Router to Backup PowerT1/E1 WAN Port or Connection Port Type, Color CableChecklist for Power-Up Power Up the RouterSystem Management Connections Port Color Connection CablePower-Up Procedure Interface Numbering Verify the Hardware ConfigurationVerify the Front Panel LED Indications LED Label LED Color or State MeaningPort Location Interface Numbering Scheme Examples1 Slot Type Interface Numbering RangePerform Initial Configuration Initial Configuration Using the Setup Command Facility Summary of the available interfaces appears User prompt appears Verify the Initial Configuration Where to Go NextTo access documentation on Cisco.com To access documentation using Cisco Connection Online CCOCisco.com Obtaining DocumentationProduct Documentation DVD Ordering DocumentationCisco Product Security Overview Reporting Security Problems in Cisco ProductsDocumentation Feedback Definitions of Service Request Severity Submitting a Service RequestObtaining Technical Assistance Cisco Technical Support & Documentation WebsiteObtaining Additional Publications and Information Page Page Page Page USA