Cisco Systems 2800 manual Electrical hazards. Statement

Page 23

Step 6 Install the plastic covers over the terminals. (See Figure 19 or Figure 20.)

Warning

The safety cover is an integral part of the product. Do not operate the unit without the safety cover installed.

 

Operating the unit without the cover in place will invalidate the safety approvals and pose a risk of fire and

 

electrical hazards. Statement 117

 

 

Step 7 Organize and secure the wires using cable ties as shown in Figure 19 or Figure 20. Make sure that the wires do not project above or below the front panel of the router.

Step 8 Turn on power to the DC circuit. Be sure to remove tape used to secure the circuit-breaker switch in the OFF position.

Figure 19 DC Wire Routing and Attachment for Cisco 2811 Routers

24-60V

--- 8A

 

-

A

+ +

B

-

Cable tie

From DC power source

111814

Plastic covers

Figure 20 DC Wire Routing and Attachment for Cisco 2821 and Cisco 2851 Routers

1

CONSOLE

 

0

 

 

AUX

24-60V

--- 12A

 

-

Cable tie

A

+

 

+

B

-

 

From DC power source

Plastic covers

111815

23

Image 23
Contents Including License and Warranty Replacement, Repair, or Refund Policy for Hardware Cisco 90-Day Limited Hardware Warranty TermsDuration of Hardware Warranty Overview To Receive a Return Materials Authorization RMA NumberSerial Number Label Location for Cisco 2801 Router Product Serial Number LocationTranslated Versions Documents, Equipment, and ToolsUser Documentation Items Included with Cisco 2801 RoutersItems Not Included Install ChassisSafety Information Page OBS! Spara Dessa Anvisningar Guarde Estas Instruções GEM Disse Anvisninger Page Statement Installing the RouterAttaching Brackets to the Router for Rack-Mounting Rack-Mounting the RouterBracket Installation for Front Mounting Installing the Router in a Rack Attaching Brackets to the Router for Wall Mounting Wall-Mounting the Router-Cisco 2811 Routers OnlyGround during normal use. Statement Installing the Router on a DesktopGrounding the Chassis Chassis Ground Connection on Cisco 2801 Chassis Connect Cables 120 VAC, 15 a 240 VAC, 10 A. Statement Power ConnectionsConnecting the Router to AC Power Protective device is rated not greater thanUse copper conductors only. Statement Connecting the Router to DC PowerSize Wire Terminal Lug Protection 60 VDC, 20 A. StatementBe connected first and disconnected last. Statement TipInsulation and conductor. Statement StepElectrical hazards. Statement DC Wire Routing and Attachment for Cisco 2811 RoutersConnecting to One Source Only-Source a or Source B Source a and Source B Wired with Opposite-Polarity Grounds WAN, LAN, and Voice Connections Connecting the Router to Backup PowerT1/E1 WAN Port or Connection Port Type, Color CablePort Color Connection Cable Power Up the RouterChecklist for Power-Up System Management ConnectionsPower-Up Procedure LED Label LED Color or State Meaning Verify the Hardware ConfigurationInterface Numbering Verify the Front Panel LED IndicationsPort Location Interface Numbering Scheme Examples1 Slot Type Interface Numbering RangePerform Initial Configuration Initial Configuration Using the Setup Command Facility Summary of the available interfaces appears User prompt appears To access documentation using Cisco Connection Online CCO Where to Go NextVerify the Initial Configuration To access documentation on Cisco.comOrdering Documentation Obtaining DocumentationCisco.com Product Documentation DVDCisco Product Security Overview Reporting Security Problems in Cisco ProductsDocumentation Feedback Cisco Technical Support & Documentation Website Submitting a Service RequestDefinitions of Service Request Severity Obtaining Technical AssistanceObtaining Additional Publications and Information Page Page Page Page USA