Approved Scenarios and Scenarios Not Approved for Dual DC Power Supply Configuration
You can connect a single DC power source to either the A input or the B input. If there are dual power sources, connect one source to the A input and one source to the B input. Both sources must be the same polarity (with respect to ground) and voltage (within 0.25 volts). Do not connect
Cisco 2851 series integrated services routers.
Caution Dual sources with
In Figure 21, either the positive source terminal or the negative source terminal is tied to ground.
Figure 21 Connecting to One Source Only—Source A or Source B
+
A-
A+
B+
B-
+
A-
A+
B+
B-
127037
In Figure 22, source A and source B share common negative terminal connections.
Figure 22 Connecting Source A and Source B with Common Negative Terminals
Va
+
+
Vb
A-
A+
B+
B-
127039
In Figure 23, source A and source B share common positive terminal connections. This is allowed only if Va equals Vb (within 0.25 V).
Caution When connecting source A and source B with common positive terminals, if source A and source B voltages are unequal by more than 0.25 V, the