Cabletron Systems HSIM-A6DP manual DOC Notice

Page 4

Notice

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

VCCI NOTICE

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT

IMPORTANT: Before utilizing this product, carefully read this License Agreement.

This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.

ii

HSIM-A6DP User’s Guide

Image 4
Contents HSIM-A6DP Page HSIM-A6DP User’s Guide DOC Notice Cabletron Software Program License HSIM-A6DP User’s Guide Declaration of Conformity HSIM-A6DP User’s Guide Contents Viii HSIM-A6DP User’s Guide Chapter Contents HSIM-A6DP User’s Guide Chapter Introduction Using this Manual Document ConventionsFeatures OverviewSpecifications Related ManualsGetting Help Your email addressHSIM-A6DP User’s Guide Chapter Installation Unpacking the HsimInstalling APIMs Removing the Apim CoverplateInstalling APIMs Installing AN Hsim Installing an Hsim in an Interface ModuleInstalling an Hsim Installing the HSIM-A6DP Installing an Hsim in a Standalone Hub HSIM-A6DP User’s Guide Chapter Local Management Local Management Keyboard Conventions Keyboard ConventionsSelecting Local Management Menu Screen Items Navigating Local Management ScreensExiting Local Management Screens Using the Return Command Accessing Local Management HSIM-A6DP ATM ScreenHSIM-A6DP ATM Screen ATM Connections Screen ATM Connections ScreenATM Connections Screen Fields ATM Connection Setup Screen 6E132-25 Local Management Interface 25 ATM Connection SetupATM Connection Setup Screen Fields Encapsulation Type Read-Only ADD/DELETE Entry Screen 1 Add/Delete Entry Screen FieldsAdding an Entry PVC Modifying an Entry PVC Deleting an Entry PVCATM Redundancy Configuration Screen ATM Redundancy Configuration ScreenATM Redundancy Configuration Screen Fields Active Port Read-Only Setting the Primary Port Setting the Redundancy StatusSetting the Active Port Setting the Activation of Redundant Port Field Setting the Revert to Primary Port FieldSetting the Periodic Test Status Field Setting the Periodic Test TimeUsing the Test Ports NOW Command Using the Reset to Factory Defaults CommandATM LEC Screen ATM LEC ScreenATM LEC Screen Fields ATM LEC Table Screen ATM LEC Table ScreenATM LEC Table Screen Fields Prev Command LEC Administration Screen 6E132-25 Local Management Interface 25 Elan AdministrationLEC Administration Screen Fields Modify Mode Changing the LEC Status Modify Mode Only 11.3 Configuring the LEC Automatically Create Mode Only11.4 Configuring the LEC Manually Create Mode Only Modifying an Existing LEC Deleting an Existing LEC Elan Properties Screen Elan Properties Screen FieldsThis field displays the ATM Address of the LEC Lecs ATM Addr Read-Only LEC ARP Cache Screen Interface 25 LEC ARP Cache ScreenLEC ARP Cache Screen Fields Search Command LEC ARP Cache Search Screen LEC ARP Cache Search ScreenLEC ARP Cache Search Screen Fields Performing a Search13 LEC ARP Cache Search Results VPI, VCI Read-Only Signalling Screen Auto Configure EnabledSignaling Screen Fields Changing the Ilmi Status Disabling the Ilmi Status Restarting UNI Changing the UNI StatusRestarting the Ilmi Setting the UNI Version Discovery Elan Setup Screen 15 The ATM Discovery Elan Setup ScreenATM Discovery Elan Setup Screen Fields Assigning the HSIM-A6DP to a discovery Elan Discovery Elan Setup Screen Using the Bandwidth Allocation Mode Feature Enabling the Bandwidth Allocation Mode FeatureEnabling the Bandwidth Allocation Mode Feature 17 The Bandwidth Allocation Mode Warning Screen Creating Pvcs with the Bandwidth Allocation Mode Enabled 6E132-25 Local Management Interface 25 ATM Connection SetupThis field displays the port Apim on which the PVC resides BW Mbps Read-Only 20.1 Add/Delete Entry Screen Fields 19 The Add/Delete Entry ScreenTotal Bandwidth On Interface Read-Only Adding an Entry PVC Modifying an Entry PVC Deleting an Entry PVC Chapter HSIM-A6DP LEDsLanview LEDs Appendix a Apim Specifications APIM-11 SpecificationsAPIM-21 Specifications OC3APIM-29 Specifications Figure A-3 APIM-29APIM-29LR Specifications Figure A-4 APIM-29LRAPIM-22 Specifications STS3APIM-67 Specifications BNCAPIM-67 Specifications HSIM-A6DP User’s Guide

HSIM-A6DP specifications

Cabletron Systems HSIM-A6DP is a versatile and powerful hardware component designed for use in networking environments. Primarily known as a High-Speed Interface Module, the HSIM-A6DP offers superior performance for connecting various network devices. Its design reflects the need for speed and reliability in an increasingly digital landscape, making it a popular choice among IT professionals and network administrators.

One of the standout features of the HSIM-A6DP is its ability to support high-speed data transmission. This module is capable of delivering up to 1 Gbps of throughput, which significantly enhances network performance. This speed is critical for applications that require quick data exchanges, such as video conferencing, large file transfers, and real-time data analysis.

Another key characteristic of the HSIM-A6DP is its dual-port functionality. This allows for increased flexibility in network configurations, enabling users to efficiently manage multiple connections. It supports both copper and fiber optic connections, catering to diverse networking requirements. The module is engineered with various fiber optic standards, ensuring compatibility with existing network setups.

The HSIM-A6DP is built with advanced technologies to ensure the robustness and reliability of the network. It uses sophisticated error detection and correction protocols, contributing to data integrity and minimizing packet loss. This reliability is essential for businesses that rely on consistent and accurate data transmission.

In terms of scalability, the HSIM-A6DP supports modular network topologies. This means it can be easily integrated into existing network infrastructures, allowing for gradual upgrades without the need for total overhauls. The module can also adapt to emerging technologies, which is a significant advantage as businesses evolve and expand.

Moreover, the HSIM-A6DP is designed with a user-friendly interface for ease of configuration and management. Its plug-and-play capability simplifies installation, allowing technicians to set up the module quickly without extensive training or technical expertise.

In summary, the Cabletron Systems HSIM-A6DP is an essential component for high-speed networking solutions. Its main features, including 1 Gbps throughput, dual-port functionality, and robust error management capabilities, make it suitable for modern networking demands. Its scalability and ease of use further enhance its appeal to businesses looking for an efficient and reliable networking solution. With the HSIM-A6DP, organizations can meet their growing data transmission needs while maintaining optimal performance.