Chapter 2
Installation
Installing the MicroLAN Module
The SmartSwitch 9000 MicroLAN Module may be installed into any of the 14 slots that are available. To install, follow the steps below:
1.Switch off the power supplies and remove all power from the SmartSwitch 9000 chassis.
2.Remove the blank panels, covering the slots that the module is being mounted in. All other slots must be covered, if modules are not being installed, to ensure proper airflow and cooling.
3.Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)
4.Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000 chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding receptacle in the lower right corner of the SmartSwitch 9000 Chassis shown in Figure
5.Remove the module from the plastic bag. Observe all precautions to prevent damage from Electrostatic Discharge (ESD).
6.Carefully examine the module, checking for damage. If any damage exists, DO NOT install the module. Contact Cabletron Systems Technical Support immediately.
7.Slide the module into a slot and lock down both the top and bottom plastic tabs, as shown in Figure