Avenview FO-DVI-XX-MM specifications Connector Electrical Characteristics

Page 15

2.7.2 Connector Electrical Characteristics

Item

Test Condition

Requirements

Contact Resistance

ANSI/EIA-364-23

20mΩ, maximum, initial per

 

 

contact mated pair

 

 

10mΩ, maximum change from

 

 

original per contact mated pair

Shell Resistance

ANSI/EIA-364-06A-83

50mΩ, maximum initial

 

Contact resistance measured from

50mΩ, maximum change from

 

receptacle shell leg to plug cable

original

 

braid. Test current = 100mA; Test

 

 

Voltage = 5V DC open circuit

 

 

maximum

 

Dielectric Withstanding Voltage

ANSI/EIA-364-20

No Flash-over, No Spark-over, No

 

Test voltage 500V DC ± 50V

Excess Leakage, No Breakdown

 

Method C, unmated and

 

 

un-mounted Barometric pressure

 

 

of 15 psi

 

Insulation Resistance

ANSI/EIA-364-21

1GΩ minimum between adjacent

 

Test voltage 500V DC ± 50V

contacts and contacts and shell

 

Method C, unmated and

 

 

un-mounted

 

Contact Current Rating

ANSI/EIA-364-70, TP-70

1.5A minimum

 

55°C, maximum ambient

 

 

85°C, maximum temperature

 

 

change

 

Applied Voltage Rating

 

40V AC(ms) continuous maximum,

 

 

on any signal pin with respect to

 

 

the shield

Electrostatic Discharge

IEC 801-2

No evidence of discharge to

 

Test un-mounted from 1kV to 8kV

contacts. Discharge to the shell is

 

in 1kV steps using 8mm ball probe

acceptable.

www.avenview.com

15

 

 

Image 15
Contents FO-DVI-XX-MM Series Table of Contents Page Getting Started Important SafeguardsSafety Instructions Regulatory Notices Federal Communications Commission FCCIntroduction Package Contents Before InstallationModel Description Installation Problem Possible Solution General TroubleshootingPart List SpecificationsDescription ’ty Material Power Consumption and DDC Power RequirementsElectrical Signal Pin AssignmentCharacteristics of DVI Connector Material Characteristics of FO-DVI-XX Cable Optical Fiber Construction and Characteristic Description FO-DVI-XX Cable Construction Dimension of FO-DVI-XX-MM Cable Items Uni SpecificationPhysical Interconnect Specification Mechanical CharacteristicsTest Condition Requirements Connector Electrical Characteristics Disclaimer