Extron electronic ISS 506 Mounting the Switcher, Tabletop placement, Rack mounting, UL guidelines

Page 18

Installation

Mounting the Switcher

Four uninstalled rubber feet are included with the seamless switcher. If you are going to rack mount the switcher, mount it before you cable it (see “Rack mounting”, below), and do not install the rubber feet. If you are not rack mounting the seamless switcher, see “Tabletop placement”, below.

Tabletop placement

For tabletop placement, install the self-adhesive rubber feet/pads (provided) onto the four corners of the bottom of the seamless switcher.

Rack mounting

UL guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the installation of the ISS 506 into a rack (figure 2-1).

1.Elevated operating ambient temperature — If the equipment installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the ISS in an environment compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified by Extron.

2.Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.

3.Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.

4.Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.Reliable earthing (grounding) — Maintain reliable grounding of rack- mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

2-2 ISS 506 Integration Seamless Switcher • Installation

Image 18
Contents Integration Seamless Switcher ISSSicherheitsanleitungen Deutsch Safety Instructions EnglishConsignes de Sécurité Français Instrucciones de seguridad EspañolFCC Class a Notice Page Table of Contents Table of Contents, cont’d ISS 506 Integration Seamless Switcher Table of Contents Iii Chapter Four SIS Programming and ControlIv ISS 506 Integration Seamless Switcher Table of Contents ISS 506 Integration Seamless Switcher Table of Contents Vi ISS 506 Integration Seamless Switcher Table of Contents One About the Integration Seamless Switchers ISS 506 Integration Seamless Switcher IntroductionAbout this Manual Extron ISS Features Introduction, cont’dISS 506 Integration Seamless Switcher Introduction Introduction, cont’d Two ISS 506 Integration Seamless Switcher Installation Mounting the SwitcherTabletop placement Rack mountingMounting the seamless switcher Mounting instructionsInput connections Installation, cont’dCabling and Rear Panel Views Video input connectionsAn SDI/HD-SDI video source to these connectors figure Audio input connectionsOutput connections Video output connectionsOptional video output connections Optional DVI output board Audio output connections Cabling and RJ-45 connector wiringControl connections Ethernet connectionWiring the network cable Choosing a network cableReset button Serial port connectionFront Panel Configuration Port 70-335-01figure 2-16, can be used for this connectionConfiguration Three Front Panel Controls and Indicators ISS 506 Integration Seamless Switcher OperationPicture adjustment and menu system controls Operation, cont’d Menu system overviewMenu system flowchart Input Configuration menu Auto Image menuSelect Output submenu Input format submenu RGBFilm Mode submenu Audio Level submenuVertical Start and Horizontal Start submenus Preview and Program Phase submenus Total Pixels submenuIncorrect active area setting Active Pixels and Active Lines submenusOutput Configuration menu RgbhvResolution and refresh rate submenu Resolution 59.94 100 120Frequency Hz Effects Configuration menu Output Type submenuSync Polarity submenu PIP Configuration submenu Dissolve Configuration submenuWipe Configuration submenu Title Key submenuPIP Border Color submenu PIP Audio submenuLogo Capture menu Image Source submenuCapture Start submenu Capture Size submenuSave Capture to File submenu User Presets menu Save submenuAdvanced Configuration menu Erase submenuAuto Image submenu Test Pattern submenuBlue Mode submenu RGB Delay submenuAuto Memories submenu Preview Switch Mode submenu Reset submenuView and Edit Communications Settings menu Serial Port submenuDhcp Mode submenu MAC Address displayIP Address, Subnet Mask, and Gateway Address submenus Scan Converter Configuration menu Size submenuCenter submenu Flicker Filter submenu Output Format submenuOutput Standard submenu Horizontal Filter submenuPower-on indications Front Panel OperationsExit menu Default Display Cycle Selecting an input to be the program output20 Selecting an input Recalling a user preset 22 Dissolving to the selected inputCapturing a logo Capture area25 Capturing a logo Configuring a logo Level27 Configuring a logo Configuring a title Title Config LevelAdjusting the picture 29 Picture adjustments flowchartAdjust knobs have no mechanical limits to their rotation Toggling background illumination on and offUsing front panel security lockouts executive modes 31 Front panel security lockout flowchartRear Panel Reset Button Performing soft system resets33 Whole switcher and absolute resets Performing a hard reset Optimizing the VideoSetting up a DVD source Optimizing the AudioTroubleshooting General checksSpecific problems Cause SolutionFour Serial Links Rear panel RS-232/RS-422 portFront panel Configuration port Optional 9-pin TRS RS-232 cableEthernet Link Default addressSIS Programming and Control, cont’d Ethernet connectionSymbols X3 =Input selection Switcher-Initiated MessagesPower-up Effect selectionWiping or dissolving in stay mode Take and busyTitle Cutting or dissolving in swap mode Switching in a PIP window or titleInput and output video type Picture adjustments @PhsX!*X2@DetX2 Automated adjustments Preview switch modePAL film mode TstX2**X2Host-to-Switcher Instructions Switcher Error ResponsesUsing the Command/Response Tables @*X!$ Command/response table for SIS commands@*X #*nnn*X$*nNnn*X$*X Wipe effect, duration, and subeffectTitle effect and title key threshold View effect and configuration ISS 506 Integration Seamless Switcher SIS ProgrammingPIP effect configuration Eff4*X#*X%*X$*XTake switch preview to program, with or without an effect ISS 506 Integration Seamless SwitcherPreview switch mode SIS Programming and ControlControl, cont’d @*X1 @VszX1 @ *B X1%@*X1 @HszX1 @*X1&HX1&*X1&*X1*X1 @*X1 @VphX1EX@,X1&*X1&*X1*X1XY VstX!*X1@*X!-U @*X!*X2U@*X!+U @*X!U @PhsX!*X2@ Spr0*X2$ @ZomX1*X1X1*X1 @ Rpr0*X2$@ +C @ ColX2 ImgX2@ *X2& C @ ColX2 @ -C @ ColX2@+Y @BrtX2 @*X2 @ConX2@*X2&Y @BrtX2 @-Y @BrtX2X3#V VolX3# X3G InX!AudX3X3@g InX!AudX3 X3#24 ISS Integration Seamless Switcher SIS Programming and Control@ *Z X1% 506ImsX3$ E7,X1&*X1&*X1*X1XYW7,X1&*X1&*X1*X1XY 7WinX1&*X1&*X1*X1 E1*X3$RF@LbuX3%*0 X3$@LbuX3%*1 32*X3%*X3# KtpX3%*X3Seamless Switcher SIS Programming and Control X3% *X1& HX3%*X1 Switcher SIS Programming and Control ISS 506 Integration4ZomX1*X1 3ZomX1 *X1X1 *X1 AldX33WinX1& *X1& *X1 *X1 X1& *X1& *X1 *X1 XYW3,X1& *X1& *X1 *X1 XY X1& *X1& *X1 *X1Vertical position Scan converter horizontal filterX4%X EncX4@X4@ ExeX4%X4-X4-X4 Integration Seamless Switcher SISVidX!AudX!TypX1StdX4#BlkX1%HrtX4$VrtX4$PreX1%X1%X1%ExeX4% Programming and ControlISS 506 Integration Seamless ResetsSIS Programming File directoryCommand/Response Table for IP SIS Commands Symbol definitionsProgramming and Control, cont’d X8$ X8@EX8!,X8#,X8$,X8$, ... X8$Em IdhX8Special Characters Five Installing the software ISS 506 Integration Seamless Switcher Switcher SoftwareISS 506 Control Program Ethernet protocol settings Software operation via EthernetSwitcher Software, cont’d Using the softwareControl window Extron ISS 506 Control Program windowEffects selections Picture control and Input Sampling buttons Configuration window I/O Configuration windowLogo Setup/Capture window Capturing a logoRecalling and configuring a logo Logo is displayed on the selected output11 Color Picker window Advanced Setup window 12 Advanced Setup windowScan Converter Setup window System Settings windowsUse Dhcp checkbox System Settings IP settings windowUnit Name field MAC Address fieldSubnet Mask field Mail Server User Password fieldGateway field Mail Server IP Address fieldSystem Settings RS-232 window Baud Rate dropboxSystem Settings Date/Time window Sync Date & Time to PC buttonDate field System Settings Passwords window Time local fieldDaylight Savings check box 20 Location of firmware upgrade files Updating firmwareConnected and the baud rate 22 Firmware loading 23 Select Startup Mode window Uploading imagesClick Add Directory Windows menus File menuOptions menu Tools menu 26 Unit Information windowContents Calls the ISS 506 Control Program help file Help menuUsing the help system Using the Button Label Generator softwareButton Label Generator 29 Extron’s Button Label Generator window Html Operation ISS 506 Integration Seamless Switcher Html Operation Downloading the StartupSystem Status Tab System StatusIP Settings fields Configuration TabSystem Configuration Html Operation, cont’dDate/Time Settings fields Gateway IP Address fieldISS Settings ISS SettingsScan converter board Scan converter boardPasswords PasswordsSetting up e-mail alerts Email AlertsFirmware Upgrade Setting up Smtp authorizationClick the Firmware Upgrade link File Management Tab File ManagementControl Tab User ControlPreset User presetsPIP settings Input presetsLogos Uploading an imageConfiguring a logo Deleting an imageAssigning recall a logo 17 Set Logo Recall slider Modifications Opening the Switcher ISS 506 Integration Seamless Switcher ModificationsInstalling an Optional SDI/HD-SDI Input Board Input board installation locationInput board installation Modifications, cont’dSecure the input board to the rear panel Installing an Optional Output Board Blank panel removalOutput board installation location Output board installation 10 Secure the output board to the standoff Closing the Switcher Installing labels in the switcher’s buttonsButton Labels Button label blanks Modifications, cont’d AAppendix a ISS 506 Integration Seamless Switcher Ethernet Connection Ping to determine Extron IP addressConnect as a Telnet client Ping to determine Web IP addressOpen Ethernet Connection, cont’dTelnet tips Escape character and Esc keyClose Local echoSet carriage return-line feed HelpLocal and remote devices Subnetting a PrimerGateways IP addresses and octetsDetermining whether devices are on the same subnet Unmasked octets are compared indicated by ? in figure A-6Ethernet Connection, cont’d AppendixBB Specifications ISS 506 Integration Seamless Switcher Reference InformationSync Reference Information, cont’d Audio outputISS 506 part numbers Part Numbers and AccessoriesAccessories Included partsReference Information, cont’d Extron Warranty Extron USA West
Related manuals
Manual 1 pages 51.84 Kb

ISS 506 specifications

The Extron ISS 506 is an advanced image scaling and processing solution designed for professional AV environments. This innovative device is tailored to meet the demands of modern presentations, conferences, and media showrooms, providing seamless integration and superior image quality.

One of the standout features of the ISS 506 is its impressive scaling capabilities. It can accept a wide range of input resolutions, ensuring compatibility with various AV sources. The device supports input resolutions up to 4K at 60 Hz, making it an ideal choice for high-resolution displays and content. Its advanced scaling technology not only allows for smooth and clear image scaling but also ensures that images look crisp and professional, regardless of the source.

Another notable characteristic is the ISS 506's powerful signal processing capabilities. It incorporates sophisticated algorithms designed to enhance image quality through deinterlacing, noise reduction, and edge enhancement. These features improve the overall visual experience, making it especially valuable for applications requiring high visual fidelity, such as art galleries and corporate boardrooms.

The ISS 506 is equipped with multiple output options, including HDMI, DisplayPort, and analog formats. This versatility allows users to connect to various display technologies without any compromise in quality. The output can be configured to accommodate different resolutions and aspect ratios, ensuring that content is displayed exactly as intended.

Additionally, the device supports advanced features like video wall processing and multi-window display. With the ability to create engaging visual experiences, users can layer multiple video sources and manage them effectively. The intuitive graphical user interface simplifies the process of setting up and controlling these complex display configurations.

In terms of connectivity, the ISS 506 offers numerous inputs, enabling users to connect laptops, cameras, and other media devices. It also features RS-232 and Ethernet control options, allowing for seamless integration with broader AV control systems.

Finally, the Extron ISS 506 is designed for reliability and ease of use, ensuring consistent performance in demanding environments. When combined with its robust feature set, this device stands out as a comprehensive solution for any professional AV application. Whether for live events, corporate meetings, or educational settings, the ISS 506 meets and exceeds the expectations of today's AV professionals.