Extron electronic ISS 506 manual Reset button, Serial port connection

Page 26

Installation, cont’d

Serial port connection

L

RS-232/422 port — Connect a host device, such as a computer or touch

 

panel control, to the ISS 506 Integration Seamless Switcher via this 9-pin D

 

connector for serial RS-232 or RS-422 control (figure 2-14).

 

 

 

 

 

 

 

 

 

 

 

 

Pin

 

RS-232

 

Function

RS-422

 

Function

 

 

 

 

 

 

 

1

 

 

Not used

 

Not used

 

 

 

2

 

TX

 

Transmit data

TX–

 

Transmit data (–)

 

RS232/422

3

 

RX

 

Receive data

RX–

 

Receive data (–)

 

 

4

 

 

Not used

 

Not used

 

 

 

5

 

Gnd

 

Signal ground

Gnd

 

Signal ground

 

 

 

6

 

 

Not used

 

Not used

 

 

7

 

 

Not used

RX+

 

Receive data (+)

 

 

8

 

 

Not used

TX+

 

Transmit data (+)

 

 

9

 

 

Not used

 

Not used

Figure 2-14 — Remote port pin assignments

See chapter 4, “SIS Programming and Control”, for definitions of the SIS commands and chapter 5, “Scaler Software”, to install and use the control software.

Reset button

M

Reset button — The Reset button initiates four levels of reset

 

LAN

 

 

 

 

to the matrix switcher. Use and Extron Tweeker or small

 

 

 

 

 

screwdriver to press and hold the button while the switcher is

 

 

 

RESET

 

 

 

 

 

running or while you power up the switcher, for different reset

 

 

 

 

 

 

 

 

 

 

 

levels.

 

 

 

 

See “Rear Panel Reset Button” in chapter 3, “Operation”, for details.

Events (mode 3) reset — Hold Reset for 3 seconds, then release it and push it again to toggle events monitoring on and off.

IP settings (mode 4) reset — Hold Reset for 6 seconds, then release it and push it again to reset the switcher’s IP functions.

NIP settings reset does not replace any user-installed firmware.

Absolute (mode 5) reset — Hold Reset for 9 seconds, then release it and push it again to restore the switcher to the default factory conditions (without resetting the firmware).

Hard reset — Hold Reset while powering up the switcher to revert to the factory default firmware (in the event that firmware incompatibility issues occur).

2-10 ISS 506 Integration Seamless Switcher • Installation

Image 26
Contents Integration Seamless Switcher ISSSicherheitsanleitungen Deutsch Safety Instructions EnglishConsignes de Sécurité Français Instrucciones de seguridad EspañolFCC Class a Notice Page Table of Contents Table of Contents, cont’d ISS 506 Integration Seamless Switcher Table of Contents Iii Chapter Four SIS Programming and ControlIv ISS 506 Integration Seamless Switcher Table of Contents ISS 506 Integration Seamless Switcher Table of Contents Vi ISS 506 Integration Seamless Switcher Table of Contents One About this Manual About the Integration Seamless SwitchersISS 506 Integration Seamless Switcher Introduction Extron ISS Features Introduction, cont’dISS 506 Integration Seamless Switcher Introduction Introduction, cont’d Two ISS 506 Integration Seamless Switcher Installation Mounting the SwitcherTabletop placement Rack mountingMounting the seamless switcher Mounting instructionsInput connections Installation, cont’dCabling and Rear Panel Views Video input connectionsAn SDI/HD-SDI video source to these connectors figure Audio input connectionsOptional video output connections Output connectionsVideo output connections Optional DVI output board Audio output connections Cabling and RJ-45 connector wiringControl connections Ethernet connectionWiring the network cable Choosing a network cableReset button Serial port connectionFront Panel Configuration Port 70-335-01figure 2-16, can be used for this connectionConfiguration Three Front Panel Controls and Indicators ISS 506 Integration Seamless Switcher OperationPicture adjustment and menu system controls Operation, cont’d Menu system overviewMenu system flowchart Select Output submenu Input Configuration menuAuto Image menu Input format submenu RGBVertical Start and Horizontal Start submenus Film Mode submenuAudio Level submenu Preview and Program Phase submenus Total Pixels submenuIncorrect active area setting Active Pixels and Active Lines submenusOutput Configuration menu RgbhvFrequency Hz Resolution and refresh rate submenuResolution 59.94 100 120 Sync Polarity submenu Effects Configuration menuOutput Type submenu PIP Configuration submenu Dissolve Configuration submenuWipe Configuration submenu Title Key submenuPIP Border Color submenu PIP Audio submenuLogo Capture menu Image Source submenuSave Capture to File submenu Capture Start submenuCapture Size submenu User Presets menu Save submenuAdvanced Configuration menu Erase submenuAuto Image submenu Test Pattern submenuAuto Memories submenu Blue Mode submenuRGB Delay submenu Preview Switch Mode submenu Reset submenuView and Edit Communications Settings menu Serial Port submenuIP Address, Subnet Mask, and Gateway Address submenus Dhcp Mode submenuMAC Address display Center submenu Scan Converter Configuration menuSize submenu Flicker Filter submenu Output Format submenuOutput Standard submenu Horizontal Filter submenuExit menu Power-on indicationsFront Panel Operations Default Display Cycle Selecting an input to be the program output20 Selecting an input Recalling a user preset 22 Dissolving to the selected inputCapturing a logo Capture area25 Capturing a logo Configuring a logo Level27 Configuring a logo Configuring a title Title Config LevelAdjusting the picture 29 Picture adjustments flowchartAdjust knobs have no mechanical limits to their rotation Toggling background illumination on and offUsing front panel security lockouts executive modes 31 Front panel security lockout flowchartRear Panel Reset Button Performing soft system resets33 Whole switcher and absolute resets Performing a hard reset Optimizing the VideoSetting up a DVD source Optimizing the AudioTroubleshooting General checksSpecific problems Cause SolutionFour Serial Links Rear panel RS-232/RS-422 portFront panel Configuration port Optional 9-pin TRS RS-232 cableEthernet Link Default addressSIS Programming and Control, cont’d Ethernet connectionSymbols X3 =Input selection Switcher-Initiated MessagesPower-up Effect selectionTitle Wiping or dissolving in stay modeTake and busy Input and output video type Cutting or dissolving in swap modeSwitching in a PIP window or title @DetX2 Picture adjustments@PhsX!*X2 Automated adjustments Preview switch modePAL film mode TstX2**X2Using the Command/Response Tables Host-to-Switcher InstructionsSwitcher Error Responses @*X!$ Command/response table for SIS commands@*X #*nnn*X$*nTitle effect and title key threshold Nnn*X$*XWipe effect, duration, and subeffect View effect and configuration ISS 506 Integration Seamless Switcher SIS ProgrammingPIP effect configuration Eff4*X#*X%*X$*XTake switch preview to program, with or without an effect ISS 506 Integration Seamless SwitcherPreview switch mode SIS Programming and ControlControl, cont’d @*X1 @VszX1 @ *B X1%@*X1 @HszX1 @*X1&HX1&*X1&*X1*X1 @*X1 @VphX1EX@,X1&*X1&*X1*X1XY VstX!*X1@*X!-U @*X!*X2U@*X!+U @*X!U @PhsX!*X2@ Spr0*X2$ @ZomX1*X1X1*X1 @ Rpr0*X2$@ +C @ ColX2 ImgX2@ *X2& C @ ColX2 @ -C @ ColX2@+Y @BrtX2 @*X2 @ConX2@*X2&Y @BrtX2 @-Y @BrtX2X3#V VolX3# X3G InX!AudX3X3@g InX!AudX3 X3#24 ISS Integration Seamless Switcher SIS Programming and Control@ *Z X1% 506ImsX3$ E7,X1&*X1&*X1*X1XYW7,X1&*X1&*X1*X1XY 7WinX1&*X1&*X1*X1 E1*X3$RF@LbuX3%*0 X3$@LbuX3%*1 32*X3%*X3# KtpX3%*X3X3%*X1 Seamless Switcher SIS Programming and ControlX3% *X1& H Switcher SIS Programming and Control ISS 506 Integration4ZomX1*X1 3ZomX1 *X1X1 *X1 AldX33WinX1& *X1& *X1 *X1 X1& *X1& *X1 *X1 XYW3,X1& *X1& *X1 *X1 XY X1& *X1& *X1 *X1Vertical position Scan converter horizontal filterX4%X EncX4@X4@ ExeX4%X4-X4-X4 Integration Seamless Switcher SISVidX!AudX!TypX1StdX4#BlkX1%HrtX4$VrtX4$PreX1%X1%X1%ExeX4% Programming and ControlISS 506 Integration Seamless ResetsSIS Programming File directoryCommand/Response Table for IP SIS Commands Symbol definitionsProgramming and Control, cont’d X8$ X8@EX8!,X8#,X8$,X8$, ... X8$Em IdhX8Special Characters Five ISS 506 Control Program Installing the softwareISS 506 Integration Seamless Switcher Switcher Software Ethernet protocol settings Software operation via EthernetSwitcher Software, cont’d Using the softwareControl window Extron ISS 506 Control Program windowEffects selections Picture control and Input Sampling buttons Configuration window I/O Configuration windowLogo Setup/Capture window Capturing a logoRecalling and configuring a logo Logo is displayed on the selected output11 Color Picker window Advanced Setup window 12 Advanced Setup windowScan Converter Setup window System Settings windowsUse Dhcp checkbox System Settings IP settings windowUnit Name field MAC Address fieldSubnet Mask field Mail Server User Password fieldGateway field Mail Server IP Address fieldSystem Settings RS-232 window Baud Rate dropboxDate field System Settings Date/Time windowSync Date & Time to PC button Daylight Savings check box System Settings Passwords windowTime local field 20 Location of firmware upgrade files Updating firmwareConnected and the baud rate 22 Firmware loading 23 Select Startup Mode window Uploading imagesClick Add Directory Options menu Windows menusFile menu Tools menu 26 Unit Information windowContents Calls the ISS 506 Control Program help file Help menuButton Label Generator Using the help systemUsing the Button Label Generator software 29 Extron’s Button Label Generator window Html Operation ISS 506 Integration Seamless Switcher Html Operation Downloading the StartupSystem Status Tab System StatusIP Settings fields Configuration TabSystem Configuration Html Operation, cont’dDate/Time Settings fields Gateway IP Address fieldISS Settings ISS SettingsScan converter board Scan converter boardPasswords PasswordsSetting up e-mail alerts Email AlertsFirmware Upgrade Setting up Smtp authorizationClick the Firmware Upgrade link File Management Tab File ManagementControl Tab User ControlPreset User presetsPIP settings Input presetsLogos Uploading an imageAssigning recall a logo Configuring a logoDeleting an image 17 Set Logo Recall slider Modifications Opening the Switcher ISS 506 Integration Seamless Switcher ModificationsInstalling an Optional SDI/HD-SDI Input Board Input board installation locationInput board installation Modifications, cont’dSecure the input board to the rear panel Installing an Optional Output Board Blank panel removalOutput board installation location Output board installation 10 Secure the output board to the standoff Button Labels Closing the SwitcherInstalling labels in the switcher’s buttons Button label blanks Modifications, cont’d AAppendix a ISS 506 Integration Seamless Switcher Ethernet Connection Ping to determine Extron IP addressConnect as a Telnet client Ping to determine Web IP addressOpen Ethernet Connection, cont’dTelnet tips Escape character and Esc keyClose Local echoSet carriage return-line feed HelpLocal and remote devices Subnetting a PrimerGateways IP addresses and octetsDetermining whether devices are on the same subnet Unmasked octets are compared indicated by ? in figure A-6Ethernet Connection, cont’d AppendixBB Specifications ISS 506 Integration Seamless Switcher Reference InformationSync Reference Information, cont’d Audio outputISS 506 part numbers Part Numbers and AccessoriesAccessories Included partsReference Information, cont’d Extron Warranty Extron USA West
Related manuals
Manual 1 pages 51.84 Kb

ISS 506 specifications

The Extron ISS 506 is an advanced image scaling and processing solution designed for professional AV environments. This innovative device is tailored to meet the demands of modern presentations, conferences, and media showrooms, providing seamless integration and superior image quality.

One of the standout features of the ISS 506 is its impressive scaling capabilities. It can accept a wide range of input resolutions, ensuring compatibility with various AV sources. The device supports input resolutions up to 4K at 60 Hz, making it an ideal choice for high-resolution displays and content. Its advanced scaling technology not only allows for smooth and clear image scaling but also ensures that images look crisp and professional, regardless of the source.

Another notable characteristic is the ISS 506's powerful signal processing capabilities. It incorporates sophisticated algorithms designed to enhance image quality through deinterlacing, noise reduction, and edge enhancement. These features improve the overall visual experience, making it especially valuable for applications requiring high visual fidelity, such as art galleries and corporate boardrooms.

The ISS 506 is equipped with multiple output options, including HDMI, DisplayPort, and analog formats. This versatility allows users to connect to various display technologies without any compromise in quality. The output can be configured to accommodate different resolutions and aspect ratios, ensuring that content is displayed exactly as intended.

Additionally, the device supports advanced features like video wall processing and multi-window display. With the ability to create engaging visual experiences, users can layer multiple video sources and manage them effectively. The intuitive graphical user interface simplifies the process of setting up and controlling these complex display configurations.

In terms of connectivity, the ISS 506 offers numerous inputs, enabling users to connect laptops, cameras, and other media devices. It also features RS-232 and Ethernet control options, allowing for seamless integration with broader AV control systems.

Finally, the Extron ISS 506 is designed for reliability and ease of use, ensuring consistent performance in demanding environments. When combined with its robust feature set, this device stands out as a comprehensive solution for any professional AV application. Whether for live events, corporate meetings, or educational settings, the ISS 506 meets and exceeds the expectations of today's AV professionals.