Extron electronic IN1508 setup guide Set up the display, Input 5 setup, Aspect ratio setup

Page 3

Set up the display

NYou may need to first set the display's aspect ratio to 1:1, pixel for pixel, or "true" mode to eliminate overscan.

Test patterns are available on IN1508 units that shipped after March 2007 and are firmware version 2.30 or higher. Earlier units may show the test pattern submenu, but it is not selectable.

1.

Navigate to Advanced > Test Pattern to access the Test Pattern selection box.

2.

Press

and

to select the Alt. Pixels test pattern. Press Enter. Adjust the display's clocking and phase as follows:

 

a.

Use the display's clocking or coarse sync controls to eliminate vertical banding or "jail bars".

 

b.

Use the display's phase or fine sync controls to eliminate horizontal noise.

3.

Navigate again to Advanced > Test Pattern to access the Test Pattern selection box.

4.

Press

and

to select the switcher's Crop test pattern. Adjust the display's horizontal and vertical shift controls until

 

all four crop lines are visible.

5.

Disable the crop pattern. No further adjustments or Auto-Image should be performed at the display.

Input 5 setup

Input 5 can accept interlaced, progressive, or HDTV component video. You need to configure the switcher to properly process input 5 as follows:

1.

Navigate to Input > Input 5 to select Input 5 selection box.

2.

Press and to select the correct setting for the video source connected to input 5. Press Enter.

Interlaced — NTSC (480i) and PAL (576i)

Progressive — 480p and 576p

HDTV — 720p, 1080i, and 1080p

Aspect ratio setup

Each input has a unique aspect ratio setting, either 4:3 (default) or 16:9. The aspect ratio is applied to all video signals that are applied to that input. If necessary, change the aspect ratio for an input as follows:

1.

If necessary, press the Input button to select the input to be set.

2.

Navigate to Input > Aspect Ratio to access the Aspect selection box.

3.

Press and to select the desired aspect ratio. Press Enter.

4.

Repeat steps 1 through 3 as necessary for the remaining inputs.

Input 8 EDID emulation

If the desired output resolution is not available from the DVI video source connected to input 8, you can use the switcher's SIS commands to set the EDID emulation for input 8. Connect a PC to the switcher's RS-232 port (l) and issue the following command:

nn*y*41#

where:

nn =

Switcher resolution (EDID):

 

 

y =

Video refresh rate:

 

00

=

Match output resolution (default)

 

0

=

Match output rate (default)

01

=

640 x 480 (VGA)

12

=

576p

1

=

50 Hz

3 = 75 Hz (24 Hz for 1080p)

02

=

800 x 600 (SVGA)

13

=

720p

2

=

60 Hz

4 = 59.94 Hz

03

=

1024 x 768 (XGA)

14

=

1080i

 

 

 

 

04

=

1280 x 1024 (SXGA)

15

=

1080p

 

 

 

 

05

=

1024 x 852

16

=

1280 x 768

 

 

 

 

06

=

1024 x 1024

17

=

1440 x 900

 

 

 

 

07

=

1366 x 768

18

=

1680 x 1050

 

 

 

 

08

=

1365 x 1024

19

=

1280 x 800

 

 

 

 

09

=

1400 x 1050

20

=

852 x 480

 

 

 

 

10

=

1600 x 1200 (UXGA)

21

=

1080p Sharp

 

 

 

 

11 =

480p

22

=

1920 x 1200

 

 

 

 

The switcher responds with "DDCnn*y]", where ] is carriage return and line feed characters.

NFor more information and a complete list of SIS commands, refer to the IN1508 User's Manual, at www.extron.com.

IN1508 • Setup Guide

3