Extron electronic IN1508 setup guide Operations PIP mode

Page 4

IN1508 — Setup Guide (cont'd)

Inputs 6 and 7 setup

RGB inputs 6 and 7 may need minor horizontal and vertical start, active pixels (horizontal), active lines (vertical), total pixels, and phase adjustments for best image quality.

1.

Press the Input button to select the input to be optimized.

2.

Execute the Auto-Imagefunction by pressing and holding the Input 6 or Input 7 button for approximately 4 seconds.

 

Release the button. Evaluate the resulting image. If it is satisfactory, this portion of the setup is complete. If the image

 

is not satisfactory, additional adjustment is necessary; perform steps 3 through 5.

3.

Navigate to Input > Advanced to access the Advanced submenu selection boxes.

4.

For soft text , vertical banding, or both, adjust the Total Pixels.

 

For fine horizontal noise, adjust the Phase.

 

For centering, adjust the Horizontal Start and Vertical Start.

 

For sizing, adjust the Horizontal Active and Vertical Active.

5.

Press and to adjust the highlighted setting.

Operations (PIP mode)

Each of the eight inputs is assigned to one of two operational groups:

Low resolution — Inputs 1 through 4 (and input 5 if it is configured as interlaced in the menu system)

High resolution — Inputs 6 through 8 (and input 5 if it is configured as progressive or HDTV in the menu system)

Input selection operation

Input selection acts differently, depending on whether PIP mode is on or off:

 

 

 

INPUT

 

 

 

 

1

2

3

4

5

6

7

8

Low Resolution

High Resolution

Input Group

Input Group

NOTE In this example, input 5 is configured as progressive component video, so it is in the high resolution group.

PIP mode off — If the PIP mode is off (the PIP On LED is off), the input button selects a new input for the main window.

PIP mode on — Pushing the input button selects a new input for either the main window or the PIP window, depending on the group (high resolution or low resolution) the input is in. The selected input replaces the previously selected input

from the same group in whichever window

 

3 1

 

8 2

SWAP

3

3

8

the replaced input had been displayed.

Press

 

Press

 

Press

 

 

 

°In the figure at right, input 3 replaces input 1 in the PIP window (a).

°In the figure at right, input 8 replaces input 6 in the main window (b).

Picture-in-picture mode operation

Red

Green

Rolloff

Uneven Frequency

10

Response

 

 

 

 

Rolloff

8

 

 

 

6

 

 

 

4

 

 

 

2

20

50

100 1000 10k 75k 100k

Output

Voltage

 

 

Frequency (Hz)

 

GreenRed

Images and

Input 3/

Input 8

LEDs swap.

The two images displayed when the PIP feature is on (the PIP On LED is lit) must come from different input groups (one high resolution and one low resolution) and you cannot toggle (swap) between two inputs in the same group.

If the primary input (the main window) is high-resolution, the secondary input (the PIP window) must be low-resolution.

If the primary input is low-resolution, the secondary input must be high-resolution.

Picture-in-picture swap

The PIP swap function swaps the main and PIP inputs. In the figure above right, when you push the Swap button:

• Input 3 replaces input 8 in the main window (c).

• Input 8 replaces input 3 in the PIP window (c).

If PIP mode is off (the PIP Mode On LED is off), the PIP swap function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

toggles between the most recently selected low-resolution and high-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resolution inputs. Unlike when PIP mode is on, however, the input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remains full screen.

 

 

 

 

 

 

 

 

 

PIP Mode

1/25

 

1/9

1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side by Side

 

 

 

 

 

 

 

 

 

 

Navigate to Advanced > PIP Mode and press and buttons to select among the

 

 

 

 

Full Screen

 

 

 

 

 

 

 

image size and position modes shown at right.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N If either side-by-side option is selected, the PIP size adjustment does not work.

Side by

Side

 

 

 

Normal Aspect

 

 

 

 

 

 

 

 

 

 

 

 

 

Extron USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.883.1568

Inside USA / Canada Only

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

Inside China Only

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

© 2010 Extron Electronics. All rights reserved. www.extron.com

Extron Middle East

+971.4.2991800 +971.4.2991880 FAX

Image 4
Contents Installation and cabling ConnectionsMounting Video inputs and outputFront Panel and Remote Control Controls and Indicators SetupPower RS-232Set up the display Input 5 setupAspect ratio setup Input 8 Edid emulationOperations PIP mode