Connect the video test generator to the device to be tested. (See Connecting the VTG Output Cables in chapter 2.)

Power On

Press the MODE/ON button to turn VTG power On. The LCD display cycles through six instructional menus (Main Menu) that tell how to operate the video test generator. The first is the identification screen (shown in the picture above). The other five are shown to the right.

Timer LED

The color of the Timer LED identifies the current operating state of the VTG. The possible Timer LED colors are:

Off = VTG inactive (no scan rate selected)

Green = VTG active (scan rate is selected), timer is running.

Red = VTG active (scan rate is selected), timer is disabled.

Blinking red & green = Time-out occurred, video is muted.

Orange = VTG is in Auto-sequence mode, timer is disabled.

Operating the Video Test Generator

Exit the Instructional Menu Cycle

To exit the instructional menu cycle, press the ▼ or ▲ button. A scan range will be displayed on the LCD screen.

View the Scan Ranges

To view the available scan ranges (i.e. TTL, VGA, Mac), hold the MODE/ON button down and press the ▼ or ▲ button. The LCD will display a different scan range each time the button is pressed. Stop when the desired scan range is displayed by the LCD.

_ There are several scan rates within each scan range. If the desired scan range is unknown, the tables in chapter 4 may be helpful. However, be aware that an updated VTG may offer scan rates that are not listed in the tables. Stepping through the scan ranges and scan rates on the VTG device will show all available scan formats.

View the Scan Rates

Press either the or button to step through the scan rates (i.e. CGA, Mac II, XGA). Continuously pressing the ▼ or ▲ button will step through all scan rates of all scan ranges. To change to a different scan range while viewing the scan rates, press and hold the MODE/ON button and press the ▼ or button.

Activate a Scan Rate

Press the SELECT button when the desired scan rate appears on the LCD readout. When the selection is made, the Timer LED will turn green and a dot test pattern will appear on the output screen of the device under test. This is test pattern #1.

To return to the main menu after activating a scan rate (cancel the scan rate), press the SELECT button.

Page 3-1

Extron • VTG 150 & VTG 200 • User’s Manual

Extron • VTG 150 & VTG 200 • User’s Manual

Page 3-2

Image 10
Contents VTG 150, VTG Video Test GeneratorsPrecautions Safety Instructions EnglishContents VTG 200 RS-232 Control and Software Chapter IntroductionReference Material Appendix a Video signal characteristics VTG 150 FeaturesVTG 200 Features IntroductionControl/remote test generator VTG 200 only Connecting the VTG Output CablesVideo output GeneralPin, TTL Output Connecting the VTG Output CablesPin HD VGA/XGA Output VTG 200 ↑ VTG 150 ↓13W3 Sun/SGI/IBM Output VTG 200 only RGB Output BNC, AnalogNTSC/PAL BNC Output VTG 200 only Adapting the VTG 150 to Other StandardsPin Signal 25-Pin Connecting TTL Output to an AT&TOperating the Video Test Generator Operating the Video Test Generator Change Scan Rate TimerPower Off Change Test PatternApplication Information VTG Formats Pattern 10 Flat Field Purity Adjustment Pattern 3 Alternating Pixels ResolutionVideo Test Patterns Setting Up Large Screen Projection Systems Video Setup GuideMonitor Applications 8AVTG 150 Apple/Mac ll Dot Test PatternTroubleshooting 9AUsing the VTG 150 to test a switcherVTG 200 RS-232 Control and Software Host/VTG 200 Communications Using the Command/Response TableVTG 200 RS-232 Control and Connection to a Computer Pin # FunctionError Responses Command/Response TableResponse Command to Host Description Definitions and AbbreviationsUsing the Software Installing the SoftwareVTG 200 Control Program 7A ↑ VTG Software Updates Part Numbers Reference MaterialVTG Software Updates Part NumbersA-3