Extron electronic SW12 VGA ARS manual Error responses, Timeout, Using the command/response table

Page 28

Error responses

When the switcher receives a valid command, it executes the command and sends a response to the host device. If the unit is unable to execute the command because the command contains invalid parameters, it returns an error response to the host.

Error response codes are:

E01 — Invalid input channel number (out of range)

E06 — Invalid input channel change (auto-switch mode active)

E09 — Invalid function (mode) parameter

E10 — Invalid command

E13 — Invalid value (out of range)

Timeout

A pause of 10 seconds or longer between command ASCII characters results in a timeout. The command operation is aborted with no other indication.

Using the command/response table

The command/response table is on the following pages. Lowercase letters are allowed in the command field only as indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command/response table.

ASCII to HEX Conversion Table

Space

Figure 3-1 ASCII-to-HEX conversion table

Symbol definitions

]= CR/LF (carriage return/line feed)

}= Carriage return (no line feed)

= Space character

X! = Input number

SW8 = 0 through 8

 

SW12 = 0 through 12

 

0

= output mute

X@= Indicates signal presence

0

= signal not present

 

1

= signal is present

X# = On/off status

0

= off

 

1

= on

X$= Volume value/range

0

- 100

X% = Switch mode

1

= normal mode

 

2

= auto switch mode

SW8/12 VGA Ars • Control 3-3

Image 28
Contents Computer Video and Audio Switchers SW8/12 VGA ArsPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice Quick Start SW8/12 VGA Ars SW8/12 VGA Ars Quick Start QS-1Quick Start SW8/12 VGA Ars, cont’d QS-2 SW8/12 VGA Ars Quick StartTable of Contents Table of Contents, cont’d One About the SW8/12 VGA Ars Switchers IntroductionAbout This Manual SW8/12 VGA Ars IntroductionFeatures Introduction, cont’d Two Installation and Operation Mounting the SW8/12 VGA Ars SwitcherDesktop placement Rack mountingMounting instructions Rack mount an SW8/12 VGA Ars unit as followsInstallation and Operation, cont’d Mounting under a desktopMounting through a desktop Cut an appropriately sized hole in the desktopRear Panel UXGA, QXGA, or HdtvCable Connections Power connectionComputer video input connections Audio input connections Pin Name Connection 5mm Stereo ConnectorVideo output connections Remote control connection Audio output connections10 SW8/12 VGA Ars Installation and Operation VSW I AAP connection15 a typical switcher application w/VSW I AAP units IR 102 remote control connection 12 SW8/12 VGA Ars Installation and OperationFront Panel Hold Press Description and ResultOperating the SW8/12 VGA Ars Switchers 14 SW8/12 VGA Ars Installation and OperationThree Remote Control via Simple Instruction Set SIS\⤀ Switcher-initiated unsolicited\⤀ messagesPin RS-232 Description RS-232 Control Port Connector ControlError responses TimeoutUsing the command/response table Symbol definitionsCommand/Response Table for SIS commands Command Ascii Telnet Response Additional descriptionUpload firmware Updating Firmware Downloading the firmwareLoading the firmware to the switcher \Program Files\Extron\FWLoaderExtron firmware loader screen Extron’s firmware loader screen 10 SW8/12 VGA Ars Control Specifications, Part Numbers, Accessories Specifications Specifications, Part Numbers, AccessoriesSW8/12 VGA Ars Specifications, Part Numbers, Accessories Audio input Part Numbers and Accessories SW8/12 VGA Ars switchersAccessories Included partsExtron’s Warranty Extron Electronics, Europe Beeldschermweg 6C