Extron electronic SW4 3G HD-SDI user manual RS-232 connector wiring

Page 19

 

N When the input rate is recognized as 270 Mbps,

 

1.485 Gpbs, or 2.97 Gbps, the output is re-clocked to the

 

recognized rate.

 

N Outputs 1 and 2 simultaneously output identical signals.

D

RS-232 connector — Connect a cable with a 3.5 mm, 3-pole

 

captive screw connector to this port for bidirectional RS-232

 

communication. Wire the connectors as shown in the following

 

figure.

Switcher

RS-232

Tx Rx

Ground

Transmit

Receive

Computer

5 1

9 6

DB9 connector (female)

pinout to control equipment

Pin

RS-232

Function

1

 

 

 

 

2

RX

 

Receive data (+)

3

TX

 

Transmit data (–)

4

 

5

Gnd

Signal ground

6

7

8

9

RS-232 connector wiring

This port has the following RS-232 protocol:

9600 baud

1 stop bit

No parity

8 data bits

See chapter 3, “Serial Communication,” for Simple Instruction Set (SIS) commands to communicate with the switcher via RS-232.

SW4 3G HD-SDI • Installation and Operation

2-5

Image 19
Contents SW4 3G HD-SDI Multi-rate SDI SwitcherSafety Instructions English Precautions安全须知 中文 Page Quick Start Guide SW4 3G HD-SDI InstallationQuick Start Guide SW4 3G HD-SDI, cont’d Operation Connecting an Input to the OutputsSW4 3G HD-SDI Quick Start Guide QS-3 QS-4 SW4 3G HD-SDI Quick Start Guide Table of Contents Table of Contents, cont’d SW4 3G HD-SDI OneIntroduction FeaturesAbout this Manual Application diagram for the SW4 3G HD-SDI switcher Introduction, cont’d Two UL rack mounting guidelines Installation and OperationInstallation Overview Rack MountingRack mounting instructions Rear Panel Connections Installation and Operation, cont’dRS-232 connector wiring SW4 3G HD-SDI switcher front panel Selecting Auto-input Switch Mode Connecting an Input to the OutputsTurning on auto-input switch mode Locking the Front Panel Resetting10 SW4 3G HD-SDI Installation and Operation Three Serial Communication Setting Up RS-232 CommunicationUsing Simple Instruction Set SIS Commands Host-to-switcher communicationsError responses Switcher-initiated messagesTimeout Symbol definitions Using the command/response tableSerial Communication, cont’d Ascii Command/response table for SIS commands@ X@ X@ X@* X$ SW4 3G HD-SDI Serial Communication Command Downloading the firmware Serial Communication, cont’d Updating the FirmwareLoading the firmware to the switcher 10 SW4 3G HD-SDI Serial Communication SW4 3G HD-SDI Serial Communication 12 SW4 3G HD-SDI Serial Communication AAppendix a Specifications Specifications, Part Numbers, and AccessoriesGeneral Part Numbers Optional accessoriesIncluded parts Central America Extron’s WarrantyExtron Electronics, Europe Beeldschermweg 6C