Extron electronic SW4 3G HD-SDI Serial Communication, cont’d, Using the command/response table

Page 28

Serial Communication, cont’d

Using the command/response table

The “Command/response table for SIS commands” begins on page 3-5. The symbols used throughout the table represent variables in the command/response fields. Lower- and uppercase letters are interchangeable, and command and response examples are shown throughout the table.

The ASCII to HEX conversion table below is for use with the command/response table.

ASCII to HEX Conversion Table

Symbol definitions

] = CR/LF (carriage return with line feed)

}= carriage return

• = space

X!

X@

X#

X$

=Input number (1 through 4)

=On/Off status 0 = off

1 = on

=Switch mode

0 = normal mode

1 = auto-input switch mode

=Input rate (0 through 3)

0 = not recognized

1 = 2.97 Gbps

2 = 1.485 Gbps

3 = 270 Mbps (megabits per second) = 0.270 Gbps

3-4 SW4 3G HD-SDI • Serial Communication

Image 28
Contents Multi-rate SDI Switcher SW4 3G HD-SDIPrecautions Safety Instructions English安全须知 中文 Page Installation Quick Start Guide SW4 3G HD-SDIOperation Connecting an Input to the Outputs Quick Start Guide SW4 3G HD-SDI, cont’dSW4 3G HD-SDI Quick Start Guide QS-3 QS-4 SW4 3G HD-SDI Quick Start Guide Table of Contents Table of Contents, cont’d One SW4 3G HD-SDIIntroduction FeaturesAbout this Manual Application diagram for the SW4 3G HD-SDI switcher Introduction, cont’d Two Installation and Operation Installation OverviewRack Mounting UL rack mounting guidelinesRack mounting instructions Installation and Operation, cont’d Rear Panel ConnectionsRS-232 connector wiring SW4 3G HD-SDI switcher front panel Connecting an Input to the Outputs Selecting Auto-input Switch ModeTurning on auto-input switch mode Resetting Locking the Front Panel10 SW4 3G HD-SDI Installation and Operation Three Setting Up RS-232 Communication Using Simple Instruction Set SIS CommandsHost-to-switcher communications Serial CommunicationError responses Switcher-initiated messagesTimeout Symbol definitions Using the command/response tableSerial Communication, cont’d Command/response table for SIS commands Ascii@ X@ X@ X@* X$ SW4 3G HD-SDI Serial Communication Command Serial Communication, cont’d Updating the Firmware Downloading the firmwareLoading the firmware to the switcher 10 SW4 3G HD-SDI Serial Communication SW4 3G HD-SDI Serial Communication 12 SW4 3G HD-SDI Serial Communication AAppendix a Specifications, Part Numbers, and Accessories SpecificationsGeneral Part Numbers Optional accessoriesIncluded parts Extron’s Warranty Central AmericaExtron Electronics, Europe Beeldschermweg 6C