Extron electronic SW4 3G HD-SDI user manual Locking the Front Panel, Resetting

Page 23

Locking the Front Panel

To prevent front panel input buttons being pressed accidentally or by unauthorized users, you can place the switcher in executive mode.

To toggle executive mode on and off, press the Input 1 button and the Input 4 button simultaneously, and hold them down for 3 seconds. All front panel LEDs flash three times, indicating the mode switch.

If an input button is pressed while the switcher is in executive mode, all front panel LEDs flash once, then the switcher reverts to the currently selected input.

NRS-232 communication remains enabled while the switcher is in executive mode.

Resetting

If the switcher needs to be reset to factory defaults, press the Input 1 button and hold it while applying power. All front panel LEDs blink once to indicate that the switcher has been reset.

NWhen the switcher is reset, the current build of firmware is used instead of the version that was loaded at the time of manufacture.

SW4 3G HD-SDI • Installation and Operation

2-9

Image 23
Contents SW4 3G HD-SDI Multi-rate SDI SwitcherSafety Instructions English Precautions安全须知 中文 Page Quick Start Guide SW4 3G HD-SDI InstallationQuick Start Guide SW4 3G HD-SDI, cont’d Operation Connecting an Input to the OutputsSW4 3G HD-SDI Quick Start Guide QS-3 QS-4 SW4 3G HD-SDI Quick Start Guide Table of Contents Table of Contents, cont’d SW4 3G HD-SDI OneAbout this Manual FeaturesIntroduction Application diagram for the SW4 3G HD-SDI switcher Introduction, cont’d Two UL rack mounting guidelines Installation and OperationInstallation Overview Rack MountingRack mounting instructions Rear Panel Connections Installation and Operation, cont’dRS-232 connector wiring SW4 3G HD-SDI switcher front panel Selecting Auto-input Switch Mode Connecting an Input to the OutputsTurning on auto-input switch mode Locking the Front Panel Resetting10 SW4 3G HD-SDI Installation and Operation Three Serial Communication Setting Up RS-232 CommunicationUsing Simple Instruction Set SIS Commands Host-to-switcher communicationsTimeout Switcher-initiated messagesError responses Serial Communication, cont’d Using the command/response tableSymbol definitions Ascii Command/response table for SIS commands@ X@ X@ X@* X$ SW4 3G HD-SDI Serial Communication Command Downloading the firmware Serial Communication, cont’d Updating the FirmwareLoading the firmware to the switcher 10 SW4 3G HD-SDI Serial Communication SW4 3G HD-SDI Serial Communication 12 SW4 3G HD-SDI Serial Communication AAppendix a Specifications Specifications, Part Numbers, and AccessoriesGeneral Included parts Optional accessoriesPart Numbers Central America Extron’s WarrantyExtron Electronics, Europe Beeldschermweg 6C