Extron electronic user manual SW4 3G HD-SDI switcher front panel

Page 20

Installation and Operation, cont’d

Front Panel Controls and Indicators

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOGNIZED

SWITCH

 

 

 

 

1

 

 

2

 

 

3

 

 

 

4

 

 

 

 

2.97 Gbps

ACTIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.485 Gbps

 

 

MODE

NORMAL

 

AUTO

 

 

 

 

 

 

 

 

 

270 Mbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4 3G HD-SDI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MULTI-RATE SDI SWITCHER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

3

 

 

4

 

 

5

 

 

 

 

 

 

 

 

 

 

SW4 3G HD-SDI switcher front panel

 

 

 

 

 

A

Auto Switch Active LED — When lit, this green LED indicates

 

that the switcher is in auto-input switch mode. In this mode, the

 

switcher automatically switches to the highest numbered input

 

with active sync pulses. When this LED is unlit, the switcher is

 

in normal (manual) mode.

 

 

 

 

 

 

 

 

 

 

 

B

Mode button — The Mode button is used with the Normal

 

button (C) or Auto button (D) to select the switching mode.

 

Mode is a secondary function of the Input 1 button. See

 

“Selecting Auto-input Switch Mode,” on the next page.

C

Normal button — The Normal button is used with the Mode

 

button (B) to select normal mode. Normal is a secondary

 

function of the Input 2 button.

 

 

 

 

 

 

 

 

 

 

 

D

Auto[switch] button — The Auto button is used with the Mode

 

button (B) to select the auto-input switch mode. Auto is a

 

secondary function of the Input 3 button.

 

 

 

 

 

E

Input buttons 1 through 4 — These buttons select inputs 1

 

through 4. They are also used to access auto-input switch and

executive modes, and to reset the unit to factory defaults.

 

The Input 1 (B), Input 2 (C), and Input 3 (D) buttons are also

 

used to toggle auto-input switch mode on and off (see “Selecting

 

Auto-input Switch Mode,” on the next page).

F

Rate indicator LEDs — These four LEDs light to indicate the

 

incoming SDI rate: Not Recognized (a rate other than those

 

represented by the other three LEDs), 2.97 Gbps, 1.485 Gbps, or

 

270 Mbps (Mbits per second).

 

When the switcher detects a valid rate on the input, the signal is

 

equalized and re-clocked to that rate on the output. If the rate is

 

not a valid one, the input is equalized, but is not re-clocked.

2-6 SW4 3G HD-SDI • Installation and Operation

Image 20
Contents Multi-rate SDI Switcher SW4 3G HD-SDIPrecautions Safety Instructions English安全须知 中文 Page Installation Quick Start Guide SW4 3G HD-SDIOperation Connecting an Input to the Outputs Quick Start Guide SW4 3G HD-SDI, cont’dSW4 3G HD-SDI Quick Start Guide QS-3 QS-4 SW4 3G HD-SDI Quick Start Guide Table of Contents Table of Contents, cont’d One SW4 3G HD-SDIAbout this Manual FeaturesIntroduction Application diagram for the SW4 3G HD-SDI switcher Introduction, cont’d Two Installation and Operation Installation OverviewRack Mounting UL rack mounting guidelinesRack mounting instructions Installation and Operation, cont’d Rear Panel ConnectionsRS-232 connector wiring SW4 3G HD-SDI switcher front panel Connecting an Input to the Outputs Selecting Auto-input Switch ModeTurning on auto-input switch mode Resetting Locking the Front Panel10 SW4 3G HD-SDI Installation and Operation Three Setting Up RS-232 Communication Using Simple Instruction Set SIS CommandsHost-to-switcher communications Serial CommunicationTimeout Switcher-initiated messagesError responses Serial Communication, cont’d Using the command/response tableSymbol definitions Command/response table for SIS commands Ascii@ X@ X@ X@* X$ SW4 3G HD-SDI Serial Communication Command Serial Communication, cont’d Updating the Firmware Downloading the firmwareLoading the firmware to the switcher 10 SW4 3G HD-SDI Serial Communication SW4 3G HD-SDI Serial Communication 12 SW4 3G HD-SDI Serial Communication AAppendix a Specifications, Part Numbers, and Accessories SpecificationsGeneral Included parts Optional accessoriesPart Numbers Extron’s Warranty Central AmericaExtron Electronics, Europe Beeldschermweg 6C