Extron electronic GSS 100 user manual SIS Control, cont’d, GSS-initiated unsolicited messages

Page 22

SISControl, cont’d

X1^ = Event data to write

 

X1& = Number of bytes to read

 

X1* = Event status fields:

Event type

 

Event state

 

Event paused

 

Error status

 

RcvBuff_startptr

 

RcvBuff_endptr

 

UsrBuff_startptr

 

UsrBuff_endptr

X1( = ASCII digit(s) representing the numeric value of the data element read from

X2)

the event buffer (leading zeroes are supressed)

= Port number

00 to 99 (00 = all ports)

X2! = Baud rate

300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200,

X2@ = Parity

28800, 38400, 57600, 115200 (9600 is default)

Odd, even, none, mark, space

NUse the first letter only.

X2#

= Data bits

7 or 8

X2$

= Stop bits

1 or 2

X2% = The number of seconds (in 10-second steps) before timeout on the IP connec- tions: (min = 1, max = 6500, default = 30 [300 seconds]). If no data is received during the timeout period, the Ethernet connection is closed. Applicable to Ethernet connection only; when connected via the RS-232 port, only the global timeout commands apply.

GSS-initiated (unsolicited) messages

When a local event, such as a front panel operation or error condition, occurs, the GSS responds by sending a message to the host. The GSS-initiated messages are listed in the following pages. The messages are underlined.

The GSS does not expect a response from the host, but the host program may request a new status.

Power-up

(C) Copyright 2005, Extron Electronics, GSS 100, Vx.xx]

The GSS issues the copyright message when it first powers on. Vx.xx is the firmware version number.

Image selection

Take]

Bsy1]

Bsy0]

The GSS issues the above sequence of commands when a front panel image selection operation or a slide show image change occurs.

The Take message indicates the change of output image.

The Bsy1 message indicates to the connected control device that the GSS is busy processing the cut or dissolve transition and is unable to respond to input commands.

The Bsy0 message indicates that the GSS is no longer busy and can respond to input commands.

Switch effect

EffX#]

The GSS initiates the Eff message when a front panel change in the image switch effect takes place.

DurX#]

The GSS initiates the Dur message when a front panel change in the dissolve duration takes place.

Output configuration

NThe Output Configuration settings apply only to the output of still images stored in the GSS; the

RGB Pass-through video is output exactly as it is input.

RteX%*X^]

The GSS initiates the Rte message when a front panel change in the output resolution takes place.

TpoX&]

The GSS initiates the Tpo message when a front panel change in the output sync format takes place.

PolX*]

The GSS initiates the Pol message when a front panel change in the output sync polarity takes place.

DlyX#]

The GSS initiates the Dly message when a front panel change in the RGB delay interval takes place.

4-4

GSS 100 Graphic Still Store • SISControl

GSS 100 Graphic Still Store • SIS Control

4-5

Image 22
Contents GSS Graphic Still StoreExtron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文 Quick Start Guide GSS Select a stored image to display as followsTable of Contents Table of Contents, cont’d One GSS 100 Graphic Still StoreIntroduction FeaturesAbout the GSS 100 Graphic Still Store Two Introduction, cont’dMounting the GSS InstallationTabletop/desktop placement Rack mountingSignal connections Installation, cont’d Rear Panel ConnectionsPower connection Cabling and RJ-45 connector wiringInstallation, cont’d Reset buttonThree OperationOperation Front Panel Controls and IndicatorsPower-on indications Front Panel OperationsMuting the video output Operation, cont’dSelecting an image to display Menu system overviewResolution submenu Switch Effect menuOutput Configuration menu Duration submenuSync format submenu RGB Delay submenuSlide Show menu Sync polarity submenuAdvanced menu Auto Switch and slide show submenuInternal Temperature display Name displayBaud Rate menu Front panel security lockout executive modeFront panel absolute reset IP address menuFour SIS ControlSIS Control SymbolsSymbol definitions Simple Instruction Set ControlSIS Control, cont’d GSS-initiated unsolicited messagesUsing the command/response table Error responsesTimeout Host-to-GSS communicationsCommand/response table for SIS commands Output rate Front panel lockout Executive modeEvent script control View, information, part number, and firmware requests ResetStore SIS Control Port configuration File managementCommand/Response Table for IP SIS Commands X3! = Device name Up to 240 charactersIP setup commands EX3%CXChapter Five GSS 100 Graphic Still Store5GSS configuration Configuring the HardwarePC configuration Html Control and IPL File ManagerConnector wiring in , Installation to make a cable Configuring the GSS using a direct PC connectionHtml Control and IPL File Manager, cont’d System Status User Name entry is not requiredUnit Name field Html Control and IPL File Manager, cont’d System SettingsIP Settings section Dhcp radio buttonsGateway IP Address field Video SettingsDate/Time Settings fields Subnet Mask fieldHtml Control and IPL File Manager, cont’d Passwords Mail AlertsFirmware Upgrade Sending an e-mail alertFile Management ControlHtml Control and IPL File Manager, cont’d Image Settings 13 Image SettingsSpecial Characters Installing the IPL File Manager and Uploading ImagesInstalling the IPL File Manager Deleting a stored imageLink File Manager IPL File Manager to start the program Uploading image filesClick Start Programs Extron Electronics IPL Tools IP Click Add DirectoryAAppendix a Reference InformationSpecifications Reference InformationReference Information, cont’d Part NumbersAssorted connectors Pre-cut cables
Related manuals
Manual 60 pages 34.24 Kb Manual 4 pages 49.96 Kb

GSS 100 specifications

Extron Electronics GSS 100 is a powerful yet compact audio signal distribution system designed to enhance the audio experience in various applications, from classrooms to corporate environments. Known for its reliability and performance, the GSS 100 serves as an essential component for signal management in modern AV systems.

One of the main features of the GSS 100 is its capability to distribute audio signals to multiple outputs while maintaining high fidelity. With the ability to handle both balanced and unbalanced signals, the GSS 100 can adapt to various audio sources and systems. This flexibility makes it suitable for a wide range of applications, including live events, presentation venues, and educational institutions.

The GSS 100 utilizes Extron’s advanced audio processing technology, which includes built-in audio mixing, equalization, and signal routing capabilities. Users can easily manage audio levels and blend multiple audio sources to create a seamless listening experience. This is particularly beneficial in environments where sound quality is paramount, allowing for adjustments that optimize the auditory experience for the audience.

Another characteristic that sets the GSS 100 apart is its intuitive user interface. The device features a straightforward control system, making it easy for users to manage and configure settings without extensive technical knowledge. Additionally, the unit is built for quick installation, with both rear and front panel connections for flexible installation options. This design consideration helps streamline setup time and minimizes disruption.

The GSS 100 also integrates seamlessly with other Extron and third-party products, enhancing its versatility in complex AV systems. With various input and output configurations, users can connect the GSS 100 to microphones, mixers, and amplifiers effortlessly. Its ability to connect to networked AV systems further extends its capabilities, enabling remote monitoring and control through software interfaces.

In conclusion, the Extron Electronics GSS 100 stands out as a premier audio signal distribution system that combines advanced technology with user-friendly features. Whether for educational purposes, corporate events, or live productions, the GSS 100 delivers reliable performance and exceptional audio quality, ensuring an optimal listening experience for any audience. As a result, it remains a popular choice among AV professionals seeking to elevate their systems with efficient and effective audio management solutions.