Extron electronic GSS 100 user manual System Status, User Name entry is not required

Page 33

HTML Control and IPL File Manager, cont’d

Accessing the HTML Pages

Access the GSS using HTML pages as follows:

1.

Start the Web browser program.

2.

Click in the browser’s Address field.

3.

Enter the GSS’s IP address in the browser’s Address field.

NIf the local system administrators have not changed the value, the factory-specified default, 192.168.254.254, is the correct value for this field.

4. If you want the browser to display a page other than the default page (such as a custom page that you have created and uploaded), follow the address with a slash (/) and the file name to open.

NThe browser’s Address field should display the address in the following format: xxx.xxx.xxx.xxx/{optional_file_ name.html}.

NThe following characters are invalid in file names: {space} + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

5.

Press the keyboard Enter key. The GSS checks to see if it is

 

password protected.

If the GSS is not password protected, proceed to step 7.

If the GSS is password protected, the Enter Network Password page (figure 5-2) appears.

Figure 5-2 — Enter Network Password page

NA User Name entry is not required.

6.

Click in the Password field and type in the appropriate

 

administrator or user password. Click the OK button.

7. The GSS checks several possibilities, in the following order, and then responds accordingly:

a. Does the address include a specific file name, such as 10.13.3.194/file_name.html? If so, the GSS outputs that HTML page to the PC or network.

b. Is there a file in the GSS’s memory that is named “index.html”?

If so, the GSS outputs “index.html” as the default startup page.

c. If neither of the above conditions is true, the GSS outputs the factory-installed default startup page, “nortxe_index.html” (figure 5-3), also known as the System Status page.

System Status Page

The System Status page (figure 5-3) provides an overall view of the status of the GSS, including various IP addresses, and the status of the RS-232 port. The System Status page is the default page that the GSS downloads when you connect to the GSS. Access the System Status page from other GSS HTML web pages by clicking the Status tab.

Figure 5-3 — System Status page

5-6 GSS 100 Graphic Still Store • HTML Control and IPL File Manager

GSS 100 Graphic Still Store • HTML Control and IPL File Manager 5-7

Image 33
Contents Graphic Still Store GSSPrecautions Extron’s WarrantyFCC Class a Notice 安全须知 中文 Select a stored image to display as follows Quick Start Guide GSSTable of Contents Table of Contents, cont’d GSS 100 Graphic Still Store OneFeatures IntroductionAbout the GSS 100 Graphic Still Store Introduction, cont’d TwoTabletop/desktop placement InstallationMounting the GSS Rack mountingPower connection Installation, cont’d Rear Panel ConnectionsSignal connections Cabling and RJ-45 connector wiringReset button Installation, cont’dOperation ThreePower-on indications Front Panel Controls and IndicatorsOperation Front Panel OperationsSelecting an image to display Operation, cont’dMuting the video output Menu system overviewOutput Configuration menu Switch Effect menuResolution submenu Duration submenuSlide Show menu RGB Delay submenuSync format submenu Sync polarity submenuInternal Temperature display Auto Switch and slide show submenuAdvanced menu Name displayFront panel absolute reset Front panel security lockout executive modeBaud Rate menu IP address menuSIS Control FourSymbol definitions SymbolsSIS Control Simple Instruction Set ControlGSS-initiated unsolicited messages SIS Control, cont’dTimeout Error responsesUsing the command/response table Host-to-GSS communicationsCommand/response table for SIS commands Front panel lockout Executive mode Output rateEvent script control Reset View, information, part number, and firmware requestsStore SIS Control File management Port configurationX3! = Device name Up to 240 characters Command/Response Table for IP SIS CommandsEX3%CX IP setup commandsGSS 100 Graphic Still Store5 Chapter FivePC configuration Configuring the HardwareGSS configuration Html Control and IPL File ManagerConfiguring the GSS using a direct PC connection Connector wiring in , Installation to make a cableHtml Control and IPL File Manager, cont’d User Name entry is not required System StatusIP Settings section Html Control and IPL File Manager, cont’d System SettingsUnit Name field Dhcp radio buttonsDate/Time Settings fields Video SettingsGateway IP Address field Subnet Mask fieldMail Alerts Html Control and IPL File Manager, cont’d PasswordsSending an e-mail alert Firmware UpgradeControl File Management13 Image Settings Html Control and IPL File Manager, cont’d Image SettingsInstalling the IPL File Manager Installing the IPL File Manager and Uploading ImagesSpecial Characters Deleting a stored imageClick Start Programs Extron Electronics IPL Tools IP Uploading image filesLink File Manager IPL File Manager to start the program Click Add DirectoryReference Information AAppendix aReference Information SpecificationsPart Numbers Reference Information, cont’dPre-cut cables Assorted connectors
Related manuals
Manual 60 pages 34.24 Kb Manual 4 pages 49.96 Kb

GSS 100 specifications

Extron Electronics GSS 100 is a powerful yet compact audio signal distribution system designed to enhance the audio experience in various applications, from classrooms to corporate environments. Known for its reliability and performance, the GSS 100 serves as an essential component for signal management in modern AV systems.

One of the main features of the GSS 100 is its capability to distribute audio signals to multiple outputs while maintaining high fidelity. With the ability to handle both balanced and unbalanced signals, the GSS 100 can adapt to various audio sources and systems. This flexibility makes it suitable for a wide range of applications, including live events, presentation venues, and educational institutions.

The GSS 100 utilizes Extron’s advanced audio processing technology, which includes built-in audio mixing, equalization, and signal routing capabilities. Users can easily manage audio levels and blend multiple audio sources to create a seamless listening experience. This is particularly beneficial in environments where sound quality is paramount, allowing for adjustments that optimize the auditory experience for the audience.

Another characteristic that sets the GSS 100 apart is its intuitive user interface. The device features a straightforward control system, making it easy for users to manage and configure settings without extensive technical knowledge. Additionally, the unit is built for quick installation, with both rear and front panel connections for flexible installation options. This design consideration helps streamline setup time and minimizes disruption.

The GSS 100 also integrates seamlessly with other Extron and third-party products, enhancing its versatility in complex AV systems. With various input and output configurations, users can connect the GSS 100 to microphones, mixers, and amplifiers effortlessly. Its ability to connect to networked AV systems further extends its capabilities, enabling remote monitoring and control through software interfaces.

In conclusion, the Extron Electronics GSS 100 stands out as a premier audio signal distribution system that combines advanced technology with user-friendly features. Whether for educational purposes, corporate events, or live productions, the GSS 100 delivers reliable performance and exceptional audio quality, ensuring an optimal listening experience for any audience. As a result, it remains a popular choice among AV professionals seeking to elevate their systems with efficient and effective audio management solutions.