ATTO Technology FC-44ES, FC-42XS, FC-41XS, FC-42ES Celerity FC-24XL, Iopc specifications

Page 12

Celerity FC-24XL

The Celerity FC-24XL is a Fibre Channel advanced storage adapter with four independent channels of 2-Gb connectivity and advanced functions. The FC-24XL is a platform with embedded processing and buffering capabilities to enable data stream manipulation, direct port-to- port transfers, offload processing, video handling and myriad other capabilities.

At the heart of the FC-24XL is the Integrated Offload & Processing Center (IOPC) using an Intel XScale® processor core and an internal 133 MHz PCI-X data bus for top performance and low latency. IOPC simplifies and augments SAN fabric management, including:

•Port-to-port data streaming

•Hardware RAID

•Backup offload

•Metadata insertion

•Data protection

•Video handling

Hardware specifications

•Four independent data channels, each supporting 2-Gb Fibre Channel performance

•2.125-Gigabit data transfer rates per channel

•400 MB/sec. maximum full duplex throughput per channel

•Supports all FC topologies: direct fabric, arbitrated loop and point-to-point

•Flash ROM for easy field upgrades

•Simultaneous multi-protocol support

IOPC specifications

•Developer’s kit for OEMs

•Intel IOP80331XScale processor core

•Supports up to 512 MB DDR 333 MHz SDRAM

•Internal 133 MHz PCI-X bus

•EDC error correction hardware capable of end- to-end data integrity

•ANSI Fibre Channel: FC-PH, FC-FCP, FC- FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA,

IETF-IPFC

Advanced FC capabilities

•Supports SNIA HBA API

•On-demand, automatic negotiation between 2- Gb and 1-Gb Fibre Channel

•Supports Target and Intitiator modes

•Supports Windows FDMI and WMI

•Exclusive Advanced Data Streaming (ADSTM) Technology

PCI Bus Specifications

•64-bit, 133 MHz PCI-X

•64/32-bit, 100/66/33 MHz PCI compatible

•PCI-X 1.0a compliant

•PCI 2.3 compliant

•3.3V PCI signaling only

Environmental & physical specifications

•Conforms to PCI full form factor standards

•Length: 6.600 inches

•Height: 4.200 inches

•Operating Temperature: 0-45ºC (32º-113ºF)

•Storage Temperature: -40º to 70ºC (-40º to 158ºF)

•Relative Humidity: 5 to 95% non-condensing

•+3.3 V@4.0A (max.)

•100 lf/m (minimum) airflow recommended

External connectivity

•Easy-to-install connection plate

•Up to four shortwave optical LC SFP pluggable transceivers

•Two optical LC SFP transceivers included

•External LEDs to show on-line and speed status for each channel

Software specifications

•Windows XP, 2000, Server 2003

•Red Hat Linux (2.4 and 2.6 kernel)

•SUSE Linux (2.6 kernel)

•Mac OS X

7 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual

Image 12
Contents Celerity FC Storage Adapters Page Page Contents Hardware installation Configuring and updating driversUpdating hardware flash Troubleshooting Fibre Channel is a key technology for storageAtto provides Fibre Channel solutions Celerity FC-42ES AdapterSoftware specifications Celerity FC-44ES AdapterPCI bus specifications Celerity FC-42XS AdapterCelerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity FC-22XH Iopc specifications Celerity FC-24XLFeatures Celerity Selection GuideCelerity FC Storage Adapters Product Fibre Channel is a key technology for storage GlossaryTerm Definition LED Hardware installation InstallationSystem requirements Fibre Channel addressFC-42ES Adapter FC-44ES Adapter FC-42XS Adapter SFP LC optical Connector FC-41XS AdapterSFF duplex LC optical connector FC controller FC-21PS AdapterFC-22XH Storage Adapter On-board hubSFP LC optical Connectors PCI-X connector FC-24XL Advanced Storage AdapterFC controllers Page Configuring and updating drivers Initial configurationWindows 2000/XP/Server Upgrading your existing Celerity FC driverPage Mac OS X driver installation, update Linux driver installation, updateNew or previous installation To update hardware flash in all operating systems Launch the Configuration ToolTo update hardware flash on a PC using the Bios utilities Updating hardware flashTroubleshooting If devices are not accessibleMac OS General suggestionsLinux Select PropertiesSelect Device Manager Appendix a Standards and compliances FCC standards radio and television interferenceCanadian standards European standardsUsage restrictions Appendix B Accessories Fibre Channel and iSCSI solutionsScsi solutions Optical CablesUltra Product Features Appendix C Scsi adapter selection guideAppendix D Contact Atto Technology, Inc