ATTO Technology FC-44ES 4-Gb operation manual Celerity FC-41XS Adapter

Page 10

Celerity FC-41XS Adapter

The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backward- compatible with existing 2-GB and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most data- intense applications.

Hardware specifications

One Fibre Channel port

4-Gigabit data transfer rates per channel

800 MB/sec. maximum full-duplex throughput per channel

Supports all FC topologies: direct fabric, arbitrated loop and point-to-point

ANSI Fibre Channel: FC-PH, FC-FCP, FC FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA

Flash ROM for easy field upgrades

FC Class 3 support

Local management and diagnostics

Buffer credits: 8 @ 512 bytes; 8 @ 2k bytes

Advanced FC capabilities

Supports SNIA HBA API

On-demand automatic negotiation among 4-Gb, 2- Gb and 1-Gb Fibre Channel

Supports target and initiator modes

Supports Windows FDMI and WMI

Exclusive Advanced Data Streaming (ADSTM) Technology

PCI bus specifications

64-bit, 133 MHz PCI-X

PCI-X 1.0a compliant

PCI 2.2 compliant

3.3V PCI signaling only

Environmental & physical specifications

Conforms to PCI low profile form factor standards

Length: 6.600 inches

Height: 2.536 inches

Operating Temperature: 0-45ºC (32º-113ºF)

Storage Temperature: -40º to 70ºC (-40º to 158ºF)

Relative Humidity: 5 to 95% non-condensing

5V@ 1.5A (max.)

100 lf/m (minimum) airflow recommended

External connectivity

Easy-to-install full height connection plate

External LEDs for on-line and speed status for each channel

Optical LC SFP transceiver included

Software specifications

Windows XP, 2000, Server 2003

Red Hat Linux (2.4 and 2.6 kernel)

SUSE Linux (2.6 kernel)

Mac OS X

5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual

Image 10
Contents Celerity FC host adapters Page Page Contents Updating hardware flash Troubleshooting Hardware installationConfiguring and updating drivers Appendix B Accessories IiiAtto provides Fibre Channel solutions Celerity FC-44ES AdapterCelerity FC-42ES Adapter Celerity FC-41ES Adapter PCI bus specifications Celerity FC-42XS AdapterCelerity FC-41XS Adapter Celerity FC-21PS Adapter Iopc specifications Celerity FC-24XL AdapterCelerity Selection Guide FeaturesCelerity FC host adapters Product Glossary Fibre Channel is a key technology for storageTerm Definition LED System requirements Hardware installationInstallation Fibre Channel addressBracket details Exhibit 3-1 FC-44ES Adapter Exhibit 3-3 FC-41ES AdapterExhibit 3-6 FC-21PS Adapter Adapter board details Exhibit 3-10 FC-42ES RoHS SFF duplex LC optical connector FC controller PCI-X connector FC controllersPage Windows 2000/XP/Server Configuring and updating driversInitial configuration Upgrading your existing Celerity FC driverPage Linux driver installation, update Mac OS X driver installation, updateNew or previous installation To update hardware flash on a PC using the Bios utilities To update hardware flash in all operating systemsLaunch the Configuration Tool Updating hardware flashMac OS TroubleshootingIf devices are not accessible General suggestionsSelect Properties LinuxSelect Device Manager Canadian standards Appendix a Standards and compliancesFCC standards radio and television interference European standardsUsage restrictions Scsi solutions Appendix B AccessoriesFibre Channel and iSCSI solutions Optical CablesUltra Product Features Appendix C Scsi adapter selection guideAppendix D Contact Atto Technology, Inc