ATTO Technology FC-44ES 4-Gb operation manual Celerity FC-42ES Adapter

Page 7

Celerity FC-42ES Adapter

The Celerity FC-42ES is a dual-channel host adapter, providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/second per channel, the FC-42ES supports the most demanding application requirements.

Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 2 GB/second (x8 PCIe). The FC- 42ES is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology investments.

Hardware specifications

•2 independent Fibre Channel ports

•4-Gigabit data transfer rates per channel

•800 MB/sec. maximum full-duplex throughput per channel

•Supports all FC topologies: direct fabric, arbitrated loop and point-to-point

•ANSI Fibre Channel: FC-PH, FC-FCP, FC, FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA

•Flash ROM for easy field upgrades

•FC Class 3 support

•Local management and diagnostics

•Buffer credits: 8 @ 512 Bytes; 8 @ 2kB

Advanced FC capabilities

•Supports SNIA HBA API

•On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel

•Supports target and initiator modes

•Supports Windows® FDMI and WMI

•Supports Exclusive Advanced Data Streaming (ADSTM) Technology

Host bus specifications

•x8 mechanical and x8 electrical PCI Express Interconnect (non RoHS); x4 mechanical and x4 electrical PCI Express interconnect

•Conforms to PCI Express Base Spec 1.0a

•Conforms to PCI Express CEM Spec 1.0a

•PCI Express to PCI/PCI-X Bridge spec 1.0

Environmental & physical specifications

•Operating Temperature: 0-45ºC (32º-113ºF)

•Storage Temperature: -40º to 70ºC (-40º to 158ºF)

•Relative Humidity: 5 to 95% non-condensing

•100 lf/m (minimum) airflow recommended

•Non RoHS

•12V@ .035A (max.)

•3.3V @ 1.42A (max.)

•Conforms to PCI standard height, half length form-factor specifications

•Length: 6.525 inches

•Height: 3.81 inches

•RoHS

•Conforms to PCI half height, half length form-factor specifications

•12V@ 04A (max.)

•3.3V @ 1.5A (max.)

•Length: 5.6 inches

•Height: 2.712 inches

External connectivity

•Easy-to-install full height connection plate

•External LEDs for on-line and speed status for each channel

•Two pluggable optical LC SFP transceivers included

Software specifications

•Windows XP, 2000 and Server 2003

•Mac OS X (10.4.x or later)

•Red Hat Linux (2.4 and 2.6 kernel)

•SUSE Linux (2.6 kernel)

2

Image 7
Contents Celerity FC host adapters Page Page Contents Appendix B Accessories Iii Hardware installationConfiguring and updating drivers Updating hardware flash TroubleshootingCelerity FC-44ES Adapter Atto provides Fibre Channel solutionsCelerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-42XS Adapter PCI bus specificationsCelerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity FC-24XL Adapter Iopc specificationsCelerity Selection Guide FeaturesCelerity FC host adapters Product Glossary Fibre Channel is a key technology for storageTerm Definition LED Fibre Channel address Hardware installationInstallation System requirementsExhibit 3-1 FC-44ES Adapter Exhibit 3-3 FC-41ES Adapter Bracket detailsExhibit 3-6 FC-21PS Adapter Adapter board details Exhibit 3-10 FC-42ES RoHS SFF duplex LC optical connector FC controller FC controllers PCI-X connectorPage Upgrading your existing Celerity FC driver Configuring and updating driversInitial configuration Windows 2000/XP/ServerPage Linux driver installation, update Mac OS X driver installation, updateNew or previous installation Updating hardware flash To update hardware flash in all operating systemsLaunch the Configuration Tool To update hardware flash on a PC using the Bios utilitiesGeneral suggestions TroubleshootingIf devices are not accessible Mac OSSelect Properties LinuxSelect Device Manager European standards Appendix a Standards and compliancesFCC standards radio and television interference Canadian standardsUsage restrictions Optical Cables Appendix B AccessoriesFibre Channel and iSCSI solutions Scsi solutionsAppendix C Scsi adapter selection guide Ultra Product FeaturesAppendix D Contact Atto Technology, Inc