Moxa Technologies 1100, 1130, 1150 UPort DB9 Pin Assignments, Terminal Block Pin Assignments

Page 26

3

Pin Assignment

UPort DB9 Pin Assignments

The UPort 1100 series uses male DB9 connectors. Pin assignments are shown in the following diagram:

DB9 (male)

Pin

RS-232

RS-422 4-wire

2-wire RS-485

 

 

 

 

 

 

 

 

RS-485

 

 

 

 

 

 

 

1

DCD (in)

TxD-(A)

-

1

 

5

2

RxD (in)

TxD+(B)

-

 

3

TxD (out)

RxD+(B)

Data+(B)

 

 

 

 

 

 

 

 

 

 

 

 

4

DTR (out)

RxD-(A)

Data-(A)

 

 

 

 

 

 

 

 

 

 

 

 

5

GND

GND

GND

 

 

 

 

 

 

 

 

 

 

 

6

DSR (in)

-

-

6

9

 

7

RTS (out)

-

-

 

 

 

 

 

 

 

 

 

 

 

 

8

CTS (in)

-

-

Terminal Block Pin Assignments

The UPort 1130/1150/1150I comes with a DB9 to terminal block converter, with pin assignments as shown below:

Terminal Block

Pin

RS-422 4-wire

2-wire RS-485

RS-485

 

1

TxD+(B)

-

 

2

TxD-(A)

-

 

3

RxD+(B)

Data+(B)

 

4

RxD-(A)

Data-(A)

 

5

GND

GND

Note that the converter maps pin 1 on the DB9 connector to pin 2 on the terminal block, and pin 2 on the DB9 connector to pin 1 on the terminal block.

Image 26
Contents UPort 1100 Series User’s Manual Second Edition, January Moxa IncCopyright Notice Table of Contents Introduction Overview Package ChecklistProduct Features Product Specifications USBLED Indicators UPort1KΩ UPort 1100 Series User’s Manual Introduction Installation and Configuration ‰ Initial Driver Installation ‰ Hardware InstallationInitial Driver Installation Page Hardware Installation Windows 98/ME and WindowsPage Page Page Page Page Configuring the COM Port Configuring the Adaptor Page Page Uninstalling the Driver Removing the AdaptorPage Install Linux driver for UPort 1100 Series Terminal Block Pin Assignments Pin AssignmentUPort DB9 Pin Assignments