Tripp Lite BC Internet, BC Personal specifications Indicator Lights, Other UPS Features

Page 5

NORM

Available on select models

Chronic mild brownouts that cause the UPS to switch to battery power frequently could leave your batteries low on charge. The adjustable voltage potentiometer allows you to prevent excessive battery drain by lowering the voltage point at which the UPS switches to battery. To keep your UPS from switching to battery during mild brownouts, turn the potentiometer clockwise to lower the voltage point as much as 18% below the nominal setting of 99 volts when set fully clockwise.

Note: Your UPS’s optimal setting will depend on the voltage conditions in your area. Adjust it clockwise only if you want to reduce how often your UPS switches to battery. Your UPS will function properly at any setting. Use caution when adjusting the potentiometer while the UPS is powering voltage-sensitive loads.

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON.

This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power.

This red light will turn ON when your UPS is providing your equipment with battery power.

Available on select models

This yellow light will turn ON after you test your UPS battery’s charge with the “Mute/Test” Switch to indicate that the UPS’s battery is less than fully charged. If it stays on continuously, contact Tripp Lite for service. The light will flash after you set the “OFF/ON” Switch to the “OFF” position to indicate that the UPS will not provide battery backup during a blackout or brownout.

Other UPS Features

AC Receptacles

The receptacles provide your connected equipment with AC line power during normal operation and battery power during black- outs and brownouts. They also protect your equipment against damaging surges and line noise. Select models, however, feature “surge-only” receptacle(s) (identified on the back of the UPS) that provide peripherals with surge protection without committing precious battery power to support them during blackouts.

RJ11 Telephone Jacks (Available on select models)

These jacks protect your equipment against telephone line surges. Connecting your equipment to these jacks is optional. Your UPS will still work properly without this connection.

Battery Replacement Door

Under normal conditions, the original battery in your UPS will last several years. Battery replacement should be performed only by qualified service personnel. Refer to “Battery Warnings” in the Safety section on page 2.

5

Image 5
Contents Quick Installation Important Safety Instructions Optional Installation Quick InstallationSet your UPS’s OFF on Switch Silence the UPS alarm SwitchesTest your UPSs battery charge Basic OperationOther UPS Features Indicator LightsSpecifications Storage & ServiceService StorageInstalación Rápida Advertencias sobre la conexión del UPS Advertencias sobre la ubicación del UPSAdvertencias sobre la conexión de equipos Advertencias sobre las bateríasConecte el no-break / sistema UPS a Instalación RápidaUna toma de energía eléctrica Regule el Interruptor OFF on encendido / apagadoInterruptores Operación BásicaArrancar en frío el no-break / sistema UPS Luces IndicadorasOtras Características de este No-break / Sistema UPS Almacenaje y ServicioAlmacenaje ServicioTodos LOS Modelos EspecificacionesInstallation Rapide Mises en garde relatives au raccord du système UPS Mises en garde relatives à lemplacement du système UPSMises en garde relatives au raccord de léquipement Mises en garde relatives à la batterieInstallation Facultative Installation RapideOpération de Base Amortir l’alarme du système d’UPSCommutateurs Démarrage à Froid de votre système d’UPSAutres Dispositifs d’UPS Voyants de SignalisationEntreposage Entreposage & ServiceCaracteristiques 93-155420000107102/00 REV.5.5/5.6