Feature Identification

Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.

1 Configuration DIP Switches: optimize UPS System operation depending on your application. See Configuration section for setting instructions.

2Operating Mode Switch: controls UPS System operation. See Operation section for setting instructions.

10 Main Ground Lug: properly grounds the UPS System to earth ground. See Configuration section for instructions.

11Multi-Speed Cooling Fan: quiet, efficient fan prolongs equipment service life.

12Hardwire AC Input/Output Cover Plate

3

“LINE”, “INVERT”, “LOAD” LEDs: show whether the UPS

 

Battery Temperature Sensing Connector (not on TMU612

13

 

System is operating from AC line power or DC battery power.

 

 

models): prolongs battery life by adjusting charge based on bat-

 

It also warns you if the connected equipment load is too high. See

 

 

 

tery temperature. Use with included cable. See Configuration

 

Operation section for instructions on reading the indicator lights.

 

 

 

section for details.

 

 

 

 

“BATTVOLT/CHRGCURR” LEDs: these three lights will turn

 

 

4

14

Low Battery Relay (not on TMU612 models): when battery

 

 

ON in several sequences to show two separate operational condi-

reaches low voltage, this relay can signal traffic controller to go

tions depending on the position of the Operating Mode Switch. See

to flashing red mode or to send low battery alert to your control

Operation section for instructions on reading indicator lights.

center. See Configuration section for details.

 

5DC Power Terminals: connect to your battery terminals. See

 

Battery Connection section for instructions.

Optional Features for alternate uses of Tripp Lite Traffic

 

 

6

AC Receptacles (not on hardwire models): allow you to connect

MOVE-UPS

equipment that would normally be plugged into a utility outlet.

 

AC

Input Cord (not on hardwire models): connects the

 

Tripp Lite’s TMU UPS models are versatile and can be used in

7

 

 

mobile applications as well, such as running AC power tools in

 

UPS

System to any source of utility- or generator-supplied

 

 

 

municipal maintenance trucks or police command vehicles.

 

AC power. SeeAC Input/Output Connection section for instructions.

 

 

 

The features listed below are available for such alternate uses.

 

Hardwire AC Input/Output Terminals (not on corded

 

8

 

 

 

models): securely connect the UPS System to electrical system

15

Remote Control Module Connector: designed only for mobile

 

input and equipment output. See AC Input/Output Connection

 

applications, this connector allows remote control from up to 50

 

section for instructions.

 

feet away with optional module, sold separately. If required,

 

Resettable Circuit Breaker: protect your UPS System against

 

contact Tripp Lite for further information.

9

 

 

 

 

damage due to overload. See Operation section for resetting

16

Load Sense Dial (not on TMU612 models): designed only for

 

instructions.

 

mobile applications, this dial sets the low load level at which the

 

 

 

 

UPS System’s inverter automatically shuts down. To guard

 

 

 

 

against inadvertent inverter shutdown, Tripp Lite recommends

 

 

 

 

you leave the dial in its factory default setting (fully clockwise).

 

 

 

 

If required, contact Tripp Lite for further information.

11

1*

4

15

3

2

16

 

 

 

 

 

 

 

13Side or Rear Mounted, Not Shown

14Side or Rear Mounted, Not Shown

9

11

1

4

15

3

2

16

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

13

Side Mounted,

 

 

 

 

 

 

 

Not Shown

 

 

 

 

 

 

 

14

Side Mounted,

 

 

 

 

 

 

 

 

Not Shown

 

 

 

 

“FOR USE WITH COPPER WIRE ONLY”

9

 

5

7

10**

HOT

IN

 

 

Front View (Corded Models)

NEUTRAL

IN

 

 

 

 

 

 

* 612 models have only one set of DIP Switches. ** Select models include front-mounted ground lug. † Available on all models except 612 models.

 

 

 

 

 

 

 

 

GROUND

IN

 

 

 

 

 

GROUND

OUT

 

 

 

 

 

HOT

OUT

 

 

 

 

 

 

NEUTRAL

OUT

 

 

 

 

5

8

12

 

10

 

 

Front View (Hardwire Models)

 

 

 

 

Rear View (Hardwire Models and Select Corded Models)

4T

Image 4
Contents Contents Warranty Registration Limited WarrantyService & Maintenance Important Safety Instructions Battery Connection WarningsLocation Warnings Equipment Connection WarningsFeature Identification MOVE-UPSSwitch Modes Indicator LightsResetting Your UPS System to Restore AC Power OperationSet Configuration DIP Switches ConfigurationGroup a DIP Switches All Models Group B DIP Switches 1012 and 2012 Models Only Mounting Horizontal MountSelect Battery Type Battery SelectionMatch Battery Amp-Hour Capacity to Your Application Battery Connection Is limited by the length and gauge of the cabling runningAC Input/Output Connection Connection for Models with Hardwire TerminalsConnection for Models with Cords and Receptacles Troubleshooting Symptom Problems Corrections