Tripp Lite SUINT1000RTXL2U, SU1000RTXL2UHV owner manual Communications

Page 9

Basic Operation (continued)

Rear Panel continued

NEMA 5-15R

NEMA 5-15/20R

Other outlet types not shown

Output Circuit Breakers Switches (Select Models Only): These resettable circuit breakers protect your UPS from output overload. If one or both breakers trip, remove some of the load on the circuit(s) and allow the UPS to cool before pressing the breaker switch(es) in to reset.

Input Cord (Select Models Only): This permanently attached power cord connects your UPS to a power outlet.

AC Receptacles (Varied by Model): These 15-, 20- and 30-amp receptacles provide your connected equipment with pure sine-wave AC output from the AC line during normal operation and from battery power during blackouts and severe brownouts. Power provided at these outlets is filtered to protect connected equipment against damaging surges and line noise. The receptacles are divided into numbered load banks, as labelled on the unit. Using PowerAlert software and cabling, load banks one and two may be individually turned off and on from a remote location, allowing users to reset or reboot connected equipment. See Serial Port Connection under Optional Connections.

Communications

“SMART” DB9 Port: Your UPS’s DB9 port can be used to monitor and control your UPS using either RS-232 or dry contact protocols. It can also be used to connect an emergency power off (EPO) switch.

RS-232 communications are very complex, but are easy to implement. The easiest way monitor and control the UPS using RS-232 is to connect the UPS to a computer with a DB9 cable and install Tripp Lite’s PowerAlert software on the connected computer.

Dry contact communications are simple, but some knowledge of electronics is necessary to configure them. The DB9 port’s pin assignments are shown in the diagram at the left. If the UPS battery is low, the UPS sends a signal by bridging pin 1 and pin 5. If utility power fails, the UPS sends a signal by bridging pin 8 and pin 5. To shut the UPS down remotely, send a 5V to 12V signal on pin 3 (using pin 5 as the (negative) ground) for at least 3.8 seconds.

You may connect your UPS to an EPO switch and a computer at once using a Tripp Lite EPO cable (not included; order accessory #73-0901 from Tripp Lite). Follow the connection procedures included with the EPO Cable.

9

Image 9
Contents SmartOnline Important Safety Instructions Rackmount Plug your UPS’s line cord into an electrical outlet Serial Port Connection Alarm Silence Basic Operation Rear Panel Communications Check the utility line for wiring problems Condition Input Abnormal SU1000RTXL2U shown SU2200RTXL2U shown Storage SU3000RTXL3U SU3000RTXL3UHV SUINT3000RTXL3U 200208159 93-2091EN
Related manuals
Manual 5 pages 32.07 Kb

SU1000RTXL2UHV, SUINT1000RTXL2U, SU1000RTXL2U specifications

The Tripp Lite SU1000RTXL2U, SUINT1000RTXL2U, and SU1000RTXL2UHV are advanced uninterruptible power supply (UPS) solutions designed to provide reliable power management for critical electronic equipment. Ideal for data centers, telecommunication systems, and sensitive electronics in both home and office settings, these UPS units are engineered to ensure continuous power supply during outages and fluctuations.

One of the standout features of the Tripp Lite SU1000RTXL2U is its high capacity, offering 1000VA/900W of power, which accommodates a wide range of devices. It employs advanced line-interactive technology that extends battery life and maximizes backup performance. With a pure sine wave output, users can rest assured that their equipment receives clean power, reducing wear and tear on electronics.

The SUINT1000RTXL2U is specifically designed for environments that require seamless integration with networking and IT systems. It provides a broad input voltage range, which helps protect against utility power fluctuations. This model is notably equipped with Advanced SmartBoost technology, enhancing power performance by allowing the UPS to compensate for voltage sags and surges.

For users needing enhanced runtime, the SU1000RTXL2UHV variant stands out with support for external battery packs. This extendable architecture allows businesses to scale their backup times according to operational needs, ensuring uninterrupted service during extended outages. Furthermore, its hot-swappable batteries facilitate easy maintenance without interrupting power to connected devices.

These models feature multiple outlets, ensuring that users have ample connectivity for their devices. The included LCD display provides real-time information about battery status, load levels, and key operating parameters, ensuring that users can monitor their power environment effectively.

In addition to their robust features, these units are designed with compact and rack-mountable configurations in mind, making them suitable for a variety of setups, including server rooms and workstations where space is at a premium.

Tripp Lite’s commitment to quality is evident, as all these UPS models meet stringent safety and performance standards, adding an extra layer of assurance for users relying on these systems to maintain critical operations. Whether for home office setups or corporate infrastructure, the SU1000RTXL2U, SUINT1000RTXL2U, and SU1000RTXL2UHV deliver exceptional performance for all power management needs.