Tripp Lite owner manual Specifications, Internet Office 500LP

Page 6

Specifications

 

Internet Office 500LP

Internet Office 500

Output Capacity (VA/Watts):

500/300

500/280

Battery Runtime (Half Load/Full Load) Minutes:

17/6

17/5

Typical Runtime (Desktop PC/15 in. monitor) Minutes:

30

30

Battery Recharge Rate:

2-4 hrs.

2-4 hrs.

Approvals:

UL, cUL

UL, cUL

Modem/Fax Protection (starts at 260V):

1 line

2 line

 

Internet Office 700

Output Capacity (VA/Watts):

700/425

Battery Runtime (Half Load/Full Load) Minutes:

17/5

Typical Runtime (Desktop PC/15 in. monitor) Minutes:

45

Battery Recharge Rate:

2-4 hrs.

Approvals:

UL, cUL

Modem/Fax Protection (starts at 260V):

2 line

ALL MODELS:

Input Voltage/Frequency (120V/60 Hz); On Line Input Voltage Range (101 - 145 volts); On Battery Output Voltage Range (120V +/- 5%); Output Waveform Line Mode (filtered sine wave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G).

FCC Part 68 Notice (U.S. only)

If your Fax Modem Protector causes harm to the telephone network, the Telephone Company may temporarily discontinue your service. If possible, they will notify you in advance. If advance notice isn’t practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of your equipment. If it does, you will be given advance notice to give you an opportunity to maintain uninterrupted service. If you experience trouble with this equipment, Fax Modem Protector, please contact the Manager of Technical Support; Tripp Lite; 1111 W. 35th Street, Chicago, Illinois 60609; Phone: (773) 869-1234, for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning. There are no repairs that can be made by the customer to the Fax Modem Protector. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your state public utility commission or corporation commission for information.)

6

Image 6
Contents Quick Installation UPS Location Warnings SafetyBattery Warnings UPS Connection WarningsSwitch on Quick InstallationTurn your UPSs power Optional All modelsSwitches Basic OperationStorage & Service ServiceStorage Specifications Internet Office 500LPAdvertencias Sobre la Conexión del Sistema UPS SeguridadAdvertencias Sobre la Ubicación del Sistema UPS Advertencias Sobre la Conexión de EquiposOpcional Todos los modelos Instalación InmediataEncienda el sistema UPS Opcional Modelos selectosOperación Básica InterruptoresLuces Indicadoras Almacenamiento Almacenamiento y ServicioOtras Características del Sistema UPS ServicioEspecíficaciones Técnicas Todos LOS ModelosAvertissements de la Connexion du Système d’Onduleur Avertissements du Placement du Système d’OnduleurSûreté Avertissements de la Connexion d’EquipementInstallation Rapide Facultatif Tous les modèlesFacultatif Certains modèles Opération de Base InterrupteursIndicateurs Lumineux Emmagasinage et Service Autres Caractéristiques du Système d’OnduleurEmmagasinage Caractéristiques Tous LES ModelesSegurança Instalação Rápida Ajuste o interruptor do UPS em posição onFuncionamento básico InterruptoresArmazenagem e Assistência Especificações