| TABLE OF CONTENTS |
|
1) OPERATION |
| |
1.1 | Operation Overview | 2 |
1.2 | 2 | |
2) SAFETY |
|
|
2.1 | Installation Safety Warnings | 3 |
2.2 | Battery Safety Warnings | 3 |
3) CONTROLS | 4 - 5 | |
4) TROUBLESHOOTING |
| |
4.1 | Troubleshooting Guide | 6 |
4.2 | Maintenance & Service | 6 |
5) SPECIFICATIONS | 7 |
Save these instructions and thoroughly read the Operation and Safety sections before using your OfficePro 280 UPS. Save the original carton and styrofoam inserts. If you require service, your warranty may be voided if the OfficePro 280 UPS
is sent back to in improper packaging.
1 • OPERATION
1.1Operation Overview
The OfficePro 280 UPS protects your equipment from all power problems: blackouts, brownouts, surges, spikes and line noise. Reliable battery power allows you to complete work, save data and safely shut down your system in the event of a blackout. OfficePro protects your equipment on both the AC and modem/network line. When AC power is present, the UPS is keeping the battery constantly charged, and connected equipment is powered directly from the AC power line.
1.2
The UPS is simple to operate and takes just a few minutes to set up. Follow the steps below before you turn the UPS ON:
STEP 1: Plug the UPS into an electrical outlet that does not share a circuit with a heavy electrical load (e.g., an air conditioner or refrigerator, etc.)
STEP 2: Determine the total VA or wattage draw of all the equipment you plan to connect to the Battery Backup Protected/Surge Protected Outlets. Look on the equipment nameplate for this information. If the equipment is listed in amps, multiply the number of amps by 120 to determine VA. (Example: 1 amp x 120 = 120 VA). The total VA for all the equipment cannot exceed 280. The total wattage cannot exceed 150.
STEP 3: Plug your computer and monitor into the three Battery Backup Protected/ Surge Protected Outlets. (Remember they provide both surge and battery backup protection.) NOTE: Do not plug laser printers into these outlets.
STEP 4: Plug your peripherals (e.g., printer, scanner or fax machine) into the three Surge Protected Outlets. (Remember, they do not supply battery backup during a utility power failure.)
19
5 • CARACTERISTIQUES
SYSTEME D’UPS OFFICEPRO 280
Puissance de Sortie (VA / Watts) | 280 / 150 | |
Tension et Fréquence de Sortie | 120V, 50/60 Hz | |
Tension et Fréquence de Sortie | 120V, 50/60 Hz | |
Temps de Secours Type | 4 - 11 minutes | |
Temps de Recharge Batterie | 4 | - 6 heures |
Temps de Transfert Type | 2 | - 4 ms |
Prises C.A. (NEMA | 6 |
|
(3 avec protection contre les surtensions, 3 avec protection contre les surtensions et secours par batterie)
Poids avec batterie | 4.4 livres (2 kg) |
Dimensions (H x L x P, en pouces) |
Niveaux de Suppression de Surtensions et de Parasites
Supprime les crêtes jusqu’à 6,000 volts aux niveaux de courant jusqu’à 19,500 ampères. Suppression des crêtes commençant aux niveaux de tension et dépassant le niveau de tension nominale. Taux d’énergie de 240 Joules. Temps de Réponse de Déclenchement:
<1 nanoseconde. Protection des crêtes dans les trois modes:
Protection Fax / Modem
Protection Fax / Modem d’une ligne unique couvre deux lignes centrales (1 paire) sur RJ11/45/
Protection Réseau
Protection de la ligne Ethernet
Homologations
Le système d’UPS OfficePro 280 est listé