Quick Start Application Example - 4

Com Port Redirector

This applications function is to redirect customer application data destined for a local serial (COM) port on a PC to the serial port of an SRC-2X. Rather than going out the local COM port, the data is transmitted across the Ethernet network using TCP/IP. The SRC-2X attached to the network receives the data and presents it on its serial port. Conversely, data sent into the serial port of the SRC-2X is transmit- ted back to the customer’s application via the network to the Com Port Redirector. Com Port Redirector then presents the data to the customer’s application as if it were from a local serial COM port.

1 – The following procedure should be performed on the SRC-2X before loading the Redirection software on the PC.

2 - Connect the supplied straight-through CAT 5 cable to the RJ-45 connector on the SRC-2X labeled Ethernet and the other end to your hub, switch or router. NOTE: If you are attaching the SRC-2X directly to your computer, you MUST use a XOVER CAT 5 cable.

3 - Connect the supplied 7.5 VDC power supply to the SRC-2X power jack. Verify that the power led and left “LINK” led above the RJ-45 is lit.

4 - Start the “Device Installer” software. a - Click on “SEARCH”

b - When the SRC-2X is found, click on the listed device. If more that one SRC- 2X is found, refer to the MAC address label attach to the bottom of the SRC- 2X case and click on the desired SRC-2X, which should be highlighted.

c - Click on the “ASSIGN IP” button, then follow the instructions for setting a stat- ic IP address, along with the subnet and gateway, if applicable.

5 – After the SRC-2X has rebooted, click the “SEARCH” button, the configured SRC-2X should be listed. NOTE: You may have to click the search button more than once after the reboot.

6 – Click on the “TELNET” button.

a - Verify that the port is set to 9999 and then press OK.

b - Press Enter within 5 seconds. The configuration settings display, followed by the setup menu options.

 

 

 

QUICK START

e-mail:support@broadcasttools.com

voice: 360.854.9559

fax: 360.854.9479

14

 

 

 

Image 14
Contents SRC-2XEthernet Serial Remote Control WHO to Contact for Help Safety InformationIntroduction Installation Product DescriptionSetup Product & Version RequestOutput Quick Start Information you’ll need to knowQuick Start Application Example Windows Socket connectionChange Setup SRC-2X, Channel 1, Basic parametersSerial Bridge/Tunneling SRC-2X, number 1 Channel 1, Basic parameters SRC-2X, number 2 Channel 1, Basic parametersSerial Tunneling Fax SRC-2X, number 3 Channel 1, Basic parameters SRC-2X, number 4 Channel 1, Basic parametersCom Port Redirector Setup Menu Options Email Notification via input triggering SRC-2X, E-mail settings Specifications TCP/IP, UDP/IP, ARP, ICMP, SNMP, TftpLimited Warranty