Tripp Lite SRC-2X operation manual Output

Page 5

SRC-2X Installation and Operation Manual

Dipswitch 4 ON, (Dipswitch 3 OFF) = String mode Only read on power up or reset Inputs 1 and 2 may be programmed to output a data string when closed. To enter program mode, enter a “P” from a terminal program. The following will be displayed:

INPUT DATA STRING ENTRY

Enter a 1 or 2, then the string data you want to be transmitted when the correspon- ding input is closed. To enter a HEX character, enter a “/” followed by the hex value. For example, if you want to send 12345(CR/LF) for input 2, enter: 212345/0D/0A and hit the ENTER key to terminate. Up to 64 characters can be entered for each input.

NOTE: /0D counts as three characters.

OUTPUT 1:

(Non-volatile string data that will be outputted when input 1 is activated).

OUTPUT 2:

(Non-volatile string data that will be outputted when input 2 is activated).

RELAY COMPARE DATA ENTRY

Enter a 3 or 4, then the string data that when received, will cause relays 1 and/or 2 to pulse for one second. The SRC-2X will receive and store whatever data it receives from the serial port, whether it be ASCII or HEX and use that to compare against incoming data. Up to 16 characters may be entered for each relay.

INPUT 1:

(Non-volatile input string data that when received and compared will pulse relay 1)

INPUT 2:

(Non-volatile input string data that when received and compared will pulse relay 2)

 

 

 

SETUp CONT’D

e-mail:support@broadcasttools.com

voice: 360.854.9559

fax: 360.854.9479

5

 

 

 

Image 5
Contents SRC-2XEthernet Serial Remote Control WHO to Contact for Help Safety InformationIntroduction Product Description InstallationProduct & Version Request SetupOutput Information you’ll need to know Quick StartWindows Socket connection Quick Start Application ExampleSRC-2X, Channel 1, Basic parameters Change SetupSerial Bridge/Tunneling SRC-2X, number 2 Channel 1, Basic parameters SRC-2X, number 1 Channel 1, Basic parametersSerial Tunneling Fax SRC-2X, number 4 Channel 1, Basic parameters SRC-2X, number 3 Channel 1, Basic parametersCom Port Redirector Setup Menu Options Email Notification via input triggering SRC-2X, E-mail settings TCP/IP, UDP/IP, ARP, ICMP, SNMP, Tftp SpecificationsLimited Warranty