Dipswitch 4 ON, (Dipswitch 3 OFF) = String mode Only read on power up or reset Inputs 1 and 2 may be programmed to output a data string when closed. To enter program mode, enter a “P” from a terminal program. The following will be displayed:
INPUT DATA STRING ENTRY
Enter a 1 or 2, then the string data you want to be transmitted when the correspon- ding input is closed. To enter a HEX character, enter a “/” followed by the hex value. For example, if you want to send 12345(CR/LF) for input 2, enter: 212345/0D/0A and hit the ENTER key to terminate. Up to 64 characters can be entered for each input.
NOTE: /0D counts as three characters.
OUTPUT 1:
OUTPUT 2:
RELAY COMPARE DATA ENTRY
Enter a 3 or 4, then the string data that when received, will cause relays 1 and/or 2 to pulse for one second. The
INPUT 1:
INPUT 2:
|
|
| SETUp CONT’D |