Tripp Lite PDUMH15ATNET Mounting the PDU, Connecting the PDU, 20U Rack Mounting Remove the screws

Page 3

Installation

Mounting the PDU

The PDU supports four primary mounting configurations: 1U Rack, 0U Rack, Wall and Under-Counter.

Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting configurations may vary.

1-11U Rack Mounting: Attach the PDU to the rack by inserting four user-supplied screws A through the PDU mounting brackets B and into the mounting holes of the rack rail as shown.

1-20U Rack Mounting: Remove the screws

Cattaching the mounting brackets to the PDU, change the orientation of the brackets as shown and reattach the brackets. Use only the screws supplied by the manufacturer or their exact equivalent (#6-32, 1/4" flat head). Attach the PDU vertically by inserting two or more user- supplied screws A through the PDU mounting brackets B and into mounting points in the rack or rack enclosure.

1-3Wall or 1-4Under-Counter Mounting: Remove the screws C attaching the mounting brackets to the PDU, change the orientation of the brackets as shown and reattach the brackets. Use only the screws supplied by the manufacturer or their exact equivalent (#6-32, 1/4" flat head). Attach the PDU to a stable mounting surface by inserting two or more user-supplied screws A through the PDU mounting brackets B and into secure points on the mounting surface.

Connecting the PDU

The PDU includes two AC power inputs: Primary and Secondary. The Primary input cord is permanently attached to the rear of the PDU. The Secondary input cord is detachable and

connects to the IEC power inlet 2 at the rear of the PDU (PDUMH15ATNET - IEC-320-C14 inlet; PDUMH20ATNET - IEC-320-C20 inlet).

B

A

1-1

B

A

 

C

1-2

 

 

 

B

 

C

A

1-3

 

 

 

 

C

B

 

 

 

 

A

1-4

2

PDUMH15ATNET

PDUMH20ATNET

3

Image 3
Contents Th Street Chicago, IL 60609 USA PDUMH15ATNET PDUMH20ATNETImportant Safety Instructions Connecting the PDU Mounting the PDU20U Rack Mounting Remove the screws Secondary input is required for the PDUs Networking the PDU Dynamic IP Address AssignmentStatic IP Address Assignment Network Interface Parameters Networking the PDU Testing Network Connection Features Network Operating Conditions Preferred Configuration Automatic Transfer SwitchQuick Test Remote Monitoring and ControlMail techsupport@tripplite.com Limited WarrantyManual del propietario Guarde Estas Instrucciones Instrucciones de seguridad importantesConexión de la PDU Montaje de la PDUInformación Instalación continuaciónConexión de la PDU continuación Funcionará sin conectar el cordón deEspecificar la emulación VT100 C Conectando Su PDU a la RedAsignación de una Dirección IP Dinámica Asignación de una Dirección IP EstáticaConectando Su PDU a la Red continuación Instalación continuación Características Condiciones de Operación de la Red Características continuaciónInterruptor de transferencia automática Correo Electrónico techsupport@tripplite.com Configuración y operación continuaciónControl y monitoreo remoto Prueba rápidaGarantía Limitada Manuel du propriétaire Conserver CES Directives Importantes consignes de sécuritéConnexion de lunité de distribution dalimentation PDU Montage de lunité de distribution dalimentation PDUInstallation suite Connexion de lunité de distribution dalimentation PDU suitePDU fonctionne sans le cordon dalimentation Spécifier lémulation VT100 C Mise en réseau de lunité de distributionAffectation dune adresse IP dynamique Affectation dune adresse IP statiqueMise en réseau de lunité de distribution suite Installation suite Caractéristiques Conditions de fonctionnement du réseau Caractéristiques suiteCircuit B Circuit a Onduleur secondaire Onduleur primaire Commutateur de transfert automatiqueCourriel techsupport@tripplite.com Configuration et fonctionnement suiteSurveillance et commande à distance Assistance à la clientèle 773Garantie Limitée

PDUMH15ATNET, PDUMH20ATNET specifications

Tripp Lite is renowned for providing robust power management solutions, and their PDUMH15ATNET and PDUMH20ATNET models are no exceptions. These intelligent power distribution units (PDUs) are specifically designed for data centers and high-density server environments, delivering advanced features that ensure reliable power distribution and management.

Both models are equipped with 15 and 20 outlets respectively, allowing for the connection of multiple devices. The outlets are NEMA 5-15R for the PDUMH15ATNET and NEMA 5-20R for the PDUMH20ATNET, providing versatility to accommodate various plug types. They also come with a 15-amp and 20-amp power input, respectively, equipped with a heavy-duty power cord that guarantees stable connectivity and reduces the risk of accidental disconnection.

One of the standout features of the PDUMH series is their integrated network management capabilities. With an embedded Ethernet port, the PDUMH15ATNET and PDUMH20ATNET offer remote management via a secure web interface, allowing users to monitor and control power distribution from virtually anywhere. This includes the ability to measure and report on energy usage, thereby providing insights for optimizing power consumption and enhancing energy efficiency.

These PDUs utilize advanced surge protection technology, helping to safeguard connected equipment from power surges and spikes. Additionally, they feature customizable outlet sequencing, which enables administrators to stagger the startup of connected devices, minimizing inrush current and preventing circuit overloads.

Further enhancing their utility, both models incorporate environmental monitoring through optional sensors that can detect changes in temperature and humidity. This capability is critical for preventing overheating and ensuring a stable operating environment for sensitive equipment.

Moreover, the PDUMH series supports various mounting options, including vertical and horizontal configurations, catering to different rack setups and preferences. Their sturdy construction and easy-to-read LED indicators ensure long-lasting performance and straightforward operation, even in demanding environments.

Overall, Tripp Lite's PDUMH15ATNET and PDUMH20ATNET represent a significant advancement in power management technology, combining reliability, versatility, and intelligence to meet the evolving needs of modern data centers and server rooms. Whether for mission-critical applications or general IT tasks, these PDUs provide the foundation for effective power management.