Tripp Lite PDUMH15ATNET, PDUMH20ATNET owner manual Network Operating Conditions

Page 9

Features continued

A B

NEMA 5-15/20R Outlets (Model PDUMH20ATNET): During normal operation, the outlets distribute AC power to connected equipment. When an outlet is live, the associated LED illuminates.

Digital Load Meter (Ammeter): The total electrical current used by the PDU is displayed on the digital meter in amperes.

Input Source Indicator: When the PDU is connected to a live AC power source, the Primary or Secondary input LED illuminates to indicate which source is supplying power to the PDU outlets.

Factory Port: The port is reserved for configuration by factory authorized personnel only. Do not connect anything to the port.

PS/2 Port: Use this port to connect a Tripp Lite ENVIROSENSE environmental sensor to provide remote temperature/humidity monitoring and a dry contact interface to control and monitor alarm, security and telecom devices. Contact Tripp Lite Customer Support at (773) 869-1234 for ordering information. Note: Do not connect a keyboard or mouse to this port.

Mini-DIN Serial Port: Use this port to provide a direct terminal connection to a computer with a terminal emulation program. A serial cable (part number 73-1025) is included with the PDU. If you need to order a replacement cable, contact Tripp Lite Customer Support at (773) 869-1234.

Ethernet Port: Use this RJ-45 jack to connect the PDU to the network with a standard Ethernet patch cable. The Link LED A and Status LED B indicate several operating conditions, as shown in the table below. This port is not compatible with PoE (Power Over Ethernet) applications.

Network Operating Conditions

ALink LED Color

Off

No Network Connection

Flashing Amber

100 Mbps Network Connection

Flashing Green

10 Mbps Network Connection

BStatus LED Color

Off

Card Not Initialized

Steady Green

Card Initialized and Operational

Flashing Amber

Error - Card Not Initialized

 

 

9

Image 9
Contents Th Street Chicago, IL 60609 USA PDUMH15ATNET PDUMH20ATNETImportant Safety Instructions Connecting the PDU Mounting the PDU20U Rack Mounting Remove the screws Secondary input is required for the PDUs Networking the PDU Dynamic IP Address AssignmentStatic IP Address Assignment Network Interface Parameters Networking the PDU Testing Network Connection Features Network Operating Conditions Preferred Configuration Automatic Transfer SwitchQuick Test Remote Monitoring and ControlMail techsupport@tripplite.com Limited WarrantyManual del propietario Guarde Estas Instrucciones Instrucciones de seguridad importantesConexión de la PDU Montaje de la PDUConexión de la PDU continuación Instalación continuaciónFuncionará sin conectar el cordón de InformaciónAsignación de una Dirección IP Dinámica Conectando Su PDU a la RedAsignación de una Dirección IP Estática Especificar la emulación VT100 CConectando Su PDU a la Red continuación Instalación continuación Características Condiciones de Operación de la Red Características continuaciónInterruptor de transferencia automática Control y monitoreo remoto Configuración y operación continuaciónPrueba rápida Correo Electrónico techsupport@tripplite.comGarantía Limitada Manuel du propriétaire Conserver CES Directives Importantes consignes de sécuritéConnexion de lunité de distribution dalimentation PDU Montage de lunité de distribution dalimentation PDUInstallation suite Connexion de lunité de distribution dalimentation PDU suitePDU fonctionne sans le cordon dalimentation Affectation dune adresse IP dynamique Mise en réseau de lunité de distributionAffectation dune adresse IP statique Spécifier lémulation VT100 CMise en réseau de lunité de distribution suite Installation suite Caractéristiques Conditions de fonctionnement du réseau Caractéristiques suiteCircuit B Circuit a Onduleur secondaire Onduleur primaire Commutateur de transfert automatiqueSurveillance et commande à distance Configuration et fonctionnement suiteAssistance à la clientèle 773 Courriel techsupport@tripplite.comGarantie Limitée

PDUMH15ATNET, PDUMH20ATNET specifications

Tripp Lite is renowned for providing robust power management solutions, and their PDUMH15ATNET and PDUMH20ATNET models are no exceptions. These intelligent power distribution units (PDUs) are specifically designed for data centers and high-density server environments, delivering advanced features that ensure reliable power distribution and management.

Both models are equipped with 15 and 20 outlets respectively, allowing for the connection of multiple devices. The outlets are NEMA 5-15R for the PDUMH15ATNET and NEMA 5-20R for the PDUMH20ATNET, providing versatility to accommodate various plug types. They also come with a 15-amp and 20-amp power input, respectively, equipped with a heavy-duty power cord that guarantees stable connectivity and reduces the risk of accidental disconnection.

One of the standout features of the PDUMH series is their integrated network management capabilities. With an embedded Ethernet port, the PDUMH15ATNET and PDUMH20ATNET offer remote management via a secure web interface, allowing users to monitor and control power distribution from virtually anywhere. This includes the ability to measure and report on energy usage, thereby providing insights for optimizing power consumption and enhancing energy efficiency.

These PDUs utilize advanced surge protection technology, helping to safeguard connected equipment from power surges and spikes. Additionally, they feature customizable outlet sequencing, which enables administrators to stagger the startup of connected devices, minimizing inrush current and preventing circuit overloads.

Further enhancing their utility, both models incorporate environmental monitoring through optional sensors that can detect changes in temperature and humidity. This capability is critical for preventing overheating and ensuring a stable operating environment for sensitive equipment.

Moreover, the PDUMH series supports various mounting options, including vertical and horizontal configurations, catering to different rack setups and preferences. Their sturdy construction and easy-to-read LED indicators ensure long-lasting performance and straightforward operation, even in demanding environments.

Overall, Tripp Lite's PDUMH15ATNET and PDUMH20ATNET represent a significant advancement in power management technology, combining reliability, versatility, and intelligence to meet the evolving needs of modern data centers and server rooms. Whether for mission-critical applications or general IT tasks, these PDUs provide the foundation for effective power management.