Tripp Lite PDUMH20ATNET, PDUMH15ATNET owner manual Features

Page 8

Features

Primary AC Input Power Cord (Model PDUMH15ATNET): The cord is permanently attached to the PDU and has a NEMA 5-15P plug.

Primary AC Input Power Cord (Model PDUMH20ATNET):

The cord is permanently attached to the PDU and has a NEMA

L5-20P plug.

Secondary AC Input Power Inlet (Model PDUMH15ATNET):

The IEC-320-C14 inlet connects to the detachable Secondary AC

Input Power Cord.

Secondary AC Input Power Inlet (Model PDUMH20ATNET):

The IEC-320-C20 inlet connects to the detachable Secondary AC

Input Power Cord.

Secondary AC Input Power Cord (Model PDUMH15ATNET): The detachable cord has an IEC-320-C13 connector and a NEMA 5-15P plug.

Secondary AC Input Power Cord (Model PDUMH20ATNET):

The detachable cord has an IEC-320-C19 connector and a NEMA

L5-20P plug.

Input Plug Adapters (Model PDUMH20ATNET): The adapters convert NEMA L5-20P input plugs to NEMA 5-20P input plugs.

NEMA 5-15R Outlets (Model PDUMH15ATNET): During normal operation, the outlets distribute AC power to connected equipment. When an outlet is live, the associated LED illuminates.

8

Image 8
Contents PDUMH15ATNET PDUMH20ATNET Th Street Chicago, IL 60609 USAImportant Safety Instructions 20U Rack Mounting Remove the screws Connecting the PDUMounting the PDU Secondary input is required for the PDUs Static IP Address Assignment Networking the PDUDynamic IP Address Assignment Network Interface Parameters Networking the PDU Testing Network Connection Features Network Operating Conditions Automatic Transfer Switch Preferred ConfigurationRemote Monitoring and Control Quick TestLimited Warranty Mail techsupport@tripplite.comManual del propietario Instrucciones de seguridad importantes Guarde Estas InstruccionesMontaje de la PDU Conexión de la PDUInstalación continuación Conexión de la PDU continuaciónFuncionará sin conectar el cordón de InformaciónConectando Su PDU a la Red Asignación de una Dirección IP DinámicaAsignación de una Dirección IP Estática Especificar la emulación VT100 CConectando Su PDU a la Red continuación Instalación continuación Características Características continuación Condiciones de Operación de la RedInterruptor de transferencia automática Configuración y operación continuación Control y monitoreo remotoPrueba rápida Correo Electrónico techsupport@tripplite.comGarantía Limitada Manuel du propriétaire Importantes consignes de sécurité Conserver CES DirectivesMontage de lunité de distribution dalimentation PDU Connexion de lunité de distribution dalimentation PDUPDU fonctionne sans le cordon dalimentation Installation suiteConnexion de lunité de distribution dalimentation PDU suite Mise en réseau de lunité de distribution Affectation dune adresse IP dynamiqueAffectation dune adresse IP statique Spécifier lémulation VT100 CMise en réseau de lunité de distribution suite Installation suite Caractéristiques Caractéristiques suite Conditions de fonctionnement du réseauCommutateur de transfert automatique Circuit B Circuit a Onduleur secondaire Onduleur primaireConfiguration et fonctionnement suite Surveillance et commande à distanceAssistance à la clientèle 773 Courriel techsupport@tripplite.comGarantie Limitée

PDUMH15ATNET, PDUMH20ATNET specifications

Tripp Lite is renowned for providing robust power management solutions, and their PDUMH15ATNET and PDUMH20ATNET models are no exceptions. These intelligent power distribution units (PDUs) are specifically designed for data centers and high-density server environments, delivering advanced features that ensure reliable power distribution and management.

Both models are equipped with 15 and 20 outlets respectively, allowing for the connection of multiple devices. The outlets are NEMA 5-15R for the PDUMH15ATNET and NEMA 5-20R for the PDUMH20ATNET, providing versatility to accommodate various plug types. They also come with a 15-amp and 20-amp power input, respectively, equipped with a heavy-duty power cord that guarantees stable connectivity and reduces the risk of accidental disconnection.

One of the standout features of the PDUMH series is their integrated network management capabilities. With an embedded Ethernet port, the PDUMH15ATNET and PDUMH20ATNET offer remote management via a secure web interface, allowing users to monitor and control power distribution from virtually anywhere. This includes the ability to measure and report on energy usage, thereby providing insights for optimizing power consumption and enhancing energy efficiency.

These PDUs utilize advanced surge protection technology, helping to safeguard connected equipment from power surges and spikes. Additionally, they feature customizable outlet sequencing, which enables administrators to stagger the startup of connected devices, minimizing inrush current and preventing circuit overloads.

Further enhancing their utility, both models incorporate environmental monitoring through optional sensors that can detect changes in temperature and humidity. This capability is critical for preventing overheating and ensuring a stable operating environment for sensitive equipment.

Moreover, the PDUMH series supports various mounting options, including vertical and horizontal configurations, catering to different rack setups and preferences. Their sturdy construction and easy-to-read LED indicators ensure long-lasting performance and straightforward operation, even in demanding environments.

Overall, Tripp Lite's PDUMH15ATNET and PDUMH20ATNET represent a significant advancement in power management technology, combining reliability, versatility, and intelligence to meet the evolving needs of modern data centers and server rooms. Whether for mission-critical applications or general IT tasks, these PDUs provide the foundation for effective power management.