Tripp Lite B072-008-IP, B072-016-IP owner manual To set the IPv4 address via the local console OSD

Page 10

1.. Product Overview

To set the IPv4 address via the local console OSD:

1.From the local console, press the left [Shift] key twice to open the OSD.

2.Press the [F2] key to open the Settings menu.

3.In the Settings menu, press the [Tab] key until the DHCP field is highlighted. Press the [Spacebar] key to toggle the DHCP field from Enabled to Disabled.

4.Pressing the [Tab] key to navigate to the additional fields, type in the desired IP Address, Subnet Mask, Gateway and DNS Server Address (optional).

5.Once the IP address is satisfactory, press the [Esc] key to save your changes. This will require that the KVM be rebooted to save the new settings.

To set the IPv6 address via the local console OSD:

1.From the local console, press the left [Shift] key twice to open the OSD.

2.Press the [F2] key to open the Settings menu, and then press the [F2] key again to open the IPv6 Settings menu.

3.In the IPv6 Settings menu, with the Mode field at the top of the screen highlighted, press the [Spacebar] key to toggle between DHCP, Stateless, and Static. DHCP is selected by default, and automatically assigns an IP address via the IPv6 DHCP server. Stateless is an option for networks with a compliant router that performs Stateless IPv6 configuration. Static allows you to manually assign an IP address.

4.Pressing the [Tab] key to navigate to the additional fields, type in the desired IP Address, Gateway, and DNS Server Address (optional). Note: DNS IP should be set to 0.0.0.0 to indicate no DNS.

5.Once the IP address is satisfactory, press the [Esc] key twice to exit and save your changes. This will require that the KVM be rebooted to save the new settings.

To set the IP address via the Web Configuration Interface:

Note:

Before logging on the first time, verify that you have the latest Java installed on your computer (Java 1.6 or higher is required). If not, you can download and install Java from http://www.java.com/en/download/index.jsp.

Only SSL connections are allowed, so you must start the IP address with HTTPS, not HTTP.

1.Open your web browser (see the Client Computer Compatibility section of this manual for browser support) and enter in the IP address of the KVM.

2.When logging into the KVM from your web browser, a Security Alert message appears to inform you that the device’s certificate is not trusted, and asks if you want to proceed. You have two options:

If you are working on a computer other than your own, accept the certificate for just this session by clicking to proceed.

If you are working at your own computer, install the certificate. Reference the instructions in the Security Certificate Installation section of this manual.

10

Image 10
Contents NetCommander IP Cat5 KVM Switch Table of Contents Legal Notice Features and BenefitsProduct Overview Target Server Compatibility SafetyTerminology Client Computer CompatibilitySystem Components NetCommander IP Unit Console KVM Switch Front ViewConsole KVM Switch Rear View Rackmount KVM Switch Front ViewStandard Console KVM Switch Instructions Rackmounting the NetCommander IPRackmount KVM Switch Rear View 2 2-Post Rack Console KVM Switch InstructionsConnecting the System Initial Settings Default IP AddressTo set the IPv4 address via the local console OSD To set the IP address via the Web Configuration InterfaceTo set the IPv6 address via the local console OSD Product Overview Product Overview Web Configuration Interface Logging Into the Web Configuration InterfaceWeb Configuration Interface Layout ToolbarServer available for access My Targets SectionConfiguration Section Server StatusFirmware Upgrade To perform a firmware upgrade, follow these stepsWeb Configuration Interface Backup/Restore To back up dataTo install an SSL Certificate To restore dataSSL Certificate Configuring the Device ID settings DeviceUsers To add an account To edit an accountTo delete a User Switch ConfigurationTo edit a port name User Targets To configure User TargetsPower Devices To Add a PDUTo Edit an existing PDU To Delete a PDUPower Outlets To configure the power outletsSerial Ports To configure the serial port settingsTo configure the security settings SecurityAccount Blocking section Authentication Web Configuration Interface Basic, User, and Group Sample Permission String To change the password Password SectionTo configure the date and time Date & TimeTo reload the Events Log Events SectionTo view the Events Log To clear the Events LogStarting a Remote Session Conducting a Remote SessionTo start a remote session Session Remote Session ToolbarPin Toolbar To mount the ISO as virtual mediaTo unmount an ISO file To set the session profileVideo To manually adjust the video settings PowerKeys To add a keyboard sequenceTo edit a predefined keyboard sequence To record a keyboard sequenceTo delete a keyboard sequence To set the Mouse Settings mode MouseConducting a Remote Session To calibrate the mouse pointers To align the mouse pointersMouse Synchronization and Keyboard/Mouse Response Time Tips Server/Serial Shared SessionExclusive Session Full ScreenLocal Console Tuning F5Move Label F1 F2 Setting Power ManagementTo Power Manage a computer To set the IPv4 address via the local console OSD To change the keyboard language Changing the HotkeyInputing and Updating DDC Information Serial Port Pinout Browser SecuritySecurity Certificate Installation Security Certificate Installation Java Security Security Certificate Installation Security Certificate Installation Technical Specifications Chrome browsers Max ResolutionVideo Resolution and Refresh Rates Warranty and Warranty Registration
Related manuals
Manual 90 pages 26.84 Kb Manual 1 pages 43.68 Kb

B070-008-19-IP, B072-008-IP, B070-016-19-IP, B072-016-IP specifications

The Tripp Lite B070-016-19-IP is a highly versatile 16-port KVM switch that serves as a reliable solution for managing multiple servers or computers from a single set of keyboard, video monitor, and mouse. This device is particularly useful in data centers, server rooms, and other environments where space and efficient management are crucial.

One of the standout features of the B070-016-19-IP is its ability to support remote access. With built-in IP capabilities, administrators can manage connected devices from anywhere in the world, enhancing operational efficiency. This is particularly important in today's increasingly mobile work environments, where remote troubleshooting and management can save time and resources.

The switch supports a variety of video resolutions up to 1920 x 1200, which ensures sharp and clear visual output, making it suitable for high-definition applications. Additionally, it is compatible with all major operating systems, further ensuring versatility in a multi-platform environment. The B070-016-19-IP features a compact design that can be easily integrated into existing systems without requiring significant reconfiguration.

The device employs advanced security measures for remote access, including enhanced encryption to protect sensitive data and server access. This includes features such as user authentication and various access levels, ensuring that only authorized personnel can manage the systems.

Built for durability and reliability, the Tripp Lite B070-016-19-IP is designed with robust construction that can withstand the rigors of daily operation in demanding environments. The device also includes a built-in firmware upgrade capability, keeping it up to date with the latest advancements and features.

In terms of connectivity, the switch offers multiple interfaces, allowing for seamless integration with various hardware configurations. It utilizes standard RJ-45 ports for connection, making installation straightforward and efficient.

Overall, the Tripp Lite B070-016-19-IP KVM switch stands out for its powerful blend of features, flexibility, and security, making it an ideal choice for IT professionals who require efficient management of multiple servers or computers. Whether used in a data center or an office, this KVM switch provides the tools necessary for effective system administration and optimal resource utilization.