SMART CAT5 SWITCH – 108/116

Figure 17 Time settings window

4.2.7.1Scan (SCN) - Label (LBL) - Time out (T/O)

SCN - In the SCN column, change the scan period.

LBL - In the LBL column, change the display period of the OSD label showing which computer is currently accessed.

T/O - When password protection is activated you can automatically disable the Management keyboard, mouse and screen after a preset time of non-use. Set this Timeout period in the T/O column.

To set the above periods:

1.On the desired line press Tab to jump to the desired column.

2.Place the cursor over one of the 3 digits and type a new number. Enter a leading zero where necessary. For example, type 040 for 40 seconds.

Typing 999 in the LBL column displays the label continuously. Typing 000 – the label will not appear.

Typing 999 in the T/O column disables the Timeout function. Warning! Typing 000 causes the Timeout function to work immediately. Minimum time should be not less than 005 seconds.

Typing 999 in the SCN column displays the screen for 999 seconds. Typing 000 – the computer screen is skipped.

4.2.8 Users

In the Settings window navigate to the Users line and press Enter. (Note! Users is only enabled if the security status is set to On, see page 17). The Users settings window appears see Figure 18.

21

Image 22
Contents Smart CAT5 Switch 108 User Guide Table of Contents Using the Control software Safety Weee compliance Technical precautions We l c o m eN t r o d u c t i o n FeaturesSystem components Smart CAT5 system configuration CompatibilityPre-installation guidelines Smart CAT5 modelsConnecting a ROC/RICC PS/2 O n n e c t i n g t h e S m a r t C AT 5 s ys t e mConnecting a ROC/RICC USB Ricc PS/2Connecting the KVM console Connecting a Ricc SUNConnecting the CAT5 cables Connecting the power supplyAvoiding general rack mounting problems Rack mounting the Smart CAT5Cascading Smart CAT5 switches Rack mounting the RICCsCascading Smart CAT5 switches Keyboard hotkeys P e r a t i n g t h e S m a r t C AT 5 s ys t e mDisplaying the OSD Navigating the OSD OSD settings F2Selecting a computer General settings Settings windowAdministrator Status a Displaying the OSD of cascaded switches 5 F7 Defaults Ports settingsTime settings Time settings window UsersUsers settings window SecuritySecurity settings window OSD Help window F1Moving the label F6 Tuning F5Scanning computers- F4 Sending monitor emulation information to ROC/RICCs F10Updating the DDC information S i n g t h e C o n t r o l s o f tw a r e Connecting the RS232 Serial cableControl software system requirements Installing and running the Control software Selecting a Com portComputer icons Icon Meaning Communication ErrorView menu Toolbar buttons Read ConfigurationWrite Configuration Get StatusSettings Logo and PasswordsEdit menu Factory default settings Loading a saved configurationReminder Supervisor Status S Password protectionAdministrator Status a User Status UConnecting the Smart CAT5 system Obtaining the Update software and latest firmwareSystem requirements for the Smart CAT5 Update software P g r a d i n g t h e S m a r t C AT 5 f i r mw a r eStarting and configuring the Smart CAT5 Update Installing the softwareConnecting the RS232 Serial cable Verifying the version numbers Com Option boxSwitch Unit box, check the Smart CAT5 Manager option Updating the firmwareRestoring factory settings Update software TroubleshootingCommunication Error message Resetting the unitsGetting the current status Electricity failure I C C S U N k e yb o a r d e m u l a t i o n S B / S U N C o m b o k e ys SUN key Combo keyTe c h n i c a l Specification s VGASafety Weee compliance201204196