4.2.11 Scanning computers– F4

Where necessary adjust the scan time in the Time Settings window, see above.

To activate scanning:

1.Press Shift twice to open the OSD.

2.Press F4. Your screen displays each active computer sequentially, with the Scan label appearing in the top left corner.

To deactivate scanning:

Press F4.

4.2.12 Tuning – F5

You can tune the image of any remote computer screen from the Select Computer window.

To adjust the screen image:

1.Navigate to the remote computer you wish to adjust.

2.Press F5. The screen image of the selected computer appears, together with the Image Tuning label.

3.Adjust the image by using the Right and Left Arrow keys.

4.When the image is satisfactory, press Esc.

Note! Picture quality is relative to distance. The further away a remote computer is from the Smart CAT5, the lower the image quality, and the more tuning needed. So place the higher resolution computers closer to the manager unit.

4.2.13 Moving the label – F6

Position the OSD label anywhere on the screen.

To position the label from the Main window:

1.Navigate to the desired computer using the Up and Down arrow keys.

2.Press F6. The selected screen image and Identification label appears.

3.Use the arrow keys to move the label to the desired position.

4.Press Esc to save and exit.

4.2.14 Sending monitor emulation information to ROC/RICCs – F10

Display Data Channel (DDC) is a VESA standard for communication between a monitor and a video adapter.

24

Image 25
Contents Smart CAT5 Switch 108 User Guide Table of Contents Using the Control software Safety Weee compliance We l c o m e Technical precautionsN t r o d u c t i o n FeaturesSystem components Compatibility Smart CAT5 system configurationSmart CAT5 models Pre-installation guidelinesO n n e c t i n g t h e S m a r t C AT 5 s ys t e m Connecting a ROC/RICC PS/2Ricc PS/2 Connecting a ROC/RICC USBConnecting the CAT5 cables Connecting a Ricc SUNConnecting the KVM console Connecting the power supplyRack mounting the Smart CAT5 Avoiding general rack mounting problemsRack mounting the RICCs Cascading Smart CAT5 switchesCascading Smart CAT5 switches Keyboard hotkeys P e r a t i n g t h e S m a r t C AT 5 s ys t e mDisplaying the OSD Navigating the OSD OSD settings F2Selecting a computer Settings window General settingsAdministrator Status a Displaying the OSD of cascaded switches Ports settings 5 F7 DefaultsTime settings Users Time settings windowSecurity Users settings windowOSD Help window F1 Security settings windowScanning computers- F4 Tuning F5Moving the label F6 Sending monitor emulation information to ROC/RICCs F10Updating the DDC information S i n g t h e C o n t r o l s o f tw a r e Connecting the RS232 Serial cableControl software system requirements Selecting a Com port Installing and running the Control softwareComputer icons Icon Meaning Communication ErrorView menu Write Configuration Read ConfigurationToolbar buttons Get StatusSettings Logo and PasswordsEdit menu Factory default settings Loading a saved configurationReminder Administrator Status a Password protectionSupervisor Status S User Status USystem requirements for the Smart CAT5 Update software Obtaining the Update software and latest firmwareConnecting the Smart CAT5 system P g r a d i n g t h e S m a r t C AT 5 f i r mw a r eStarting and configuring the Smart CAT5 Update Installing the softwareConnecting the RS232 Serial cable Com Option box Verifying the version numbersUpdating the firmware Switch Unit box, check the Smart CAT5 Manager optionUpdate software Troubleshooting Restoring factory settingsCommunication Error message Resetting the unitsGetting the current status Electricity failure I C C S U N k e yb o a r d e m u l a t i o n SUN key Combo key S B / S U N C o m b o k e ysVGA Te c h n i c a l Specification sWeee compliance Safety201204196