Tripp Lite 116 Password protection, Administrator Status a, Supervisor Status S, User Status U

Page 33

USER GUIDE

5.4 Password protection

When the Smart CAT5 system is password protected, the Control software behaves in exactly the same way as the OSD. You must type in the required password to access the Control software. The access you gain depends on the security status – exactly as with the OSD.

To change the security access, close and reopen the Control software, and type in the different password.

5.4.1Administrator (Status A)

The Administrator can:

Set and modify all Passwords and security profiles

Fully access any computer

Use all functions

5.4.2Supervisor (Status S)

The Supervisor can:

Fully access any computer

Scan computers.

5.4.3 User (Status U)

There are 6 different Users in the Smart CAT5 system. Each User has a Profile that defines the access level to different computers. There are 3 different access levels. These are:

Y – Full access to a particular computer

V –Viewing access only, to a particular computer (No keyboard/mouse functionality)

N – No access to a particular computer

The Administrator defines the desired access levels of each User Profile. This is done in the Setting box. By default the User Profile settings are full access.

32

Image 33
Contents Smart CAT5 Switch 108 User Guide Table of Contents Using the Control software Safety Weee compliance We l c o m e Technical precautionsFeatures N t r o d u c t i o nSystem components Compatibility Smart CAT5 system configurationSmart CAT5 models Pre-installation guidelinesO n n e c t i n g t h e S m a r t C AT 5 s ys t e m Connecting a ROC/RICC PS/2Ricc PS/2 Connecting a ROC/RICC USBConnecting the CAT5 cables Connecting a Ricc SUNConnecting the KVM console Connecting the power supplyRack mounting the Smart CAT5 Avoiding general rack mounting problemsRack mounting the RICCs Cascading Smart CAT5 switchesCascading Smart CAT5 switches P e r a t i n g t h e S m a r t C AT 5 s ys t e m Keyboard hotkeysDisplaying the OSD OSD settings F2 Navigating the OSDSelecting a computer Settings window General settingsAdministrator Status a Displaying the OSD of cascaded switches Ports settings 5 F7 DefaultsTime settings Users Time settings windowSecurity Users settings windowOSD Help window F1 Security settings windowScanning computers- F4 Tuning F5Moving the label F6 Sending monitor emulation information to ROC/RICCs F10Updating the DDC information Connecting the RS232 Serial cable S i n g t h e C o n t r o l s o f tw a r eControl software system requirements Selecting a Com port Installing and running the Control softwareCommunication Error Computer icons Icon MeaningView menu Write Configuration Read ConfigurationToolbar buttons Get StatusLogo and Passwords SettingsEdit menu Loading a saved configuration Factory default settingsReminder Administrator Status a Password protectionSupervisor Status S User Status USystem requirements for the Smart CAT5 Update software Obtaining the Update software and latest firmwareConnecting the Smart CAT5 system P g r a d i n g t h e S m a r t C AT 5 f i r mw a r eInstalling the software Starting and configuring the Smart CAT5 UpdateConnecting the RS232 Serial cable Com Option box Verifying the version numbersUpdating the firmware Switch Unit box, check the Smart CAT5 Manager optionUpdate software Troubleshooting Restoring factory settingsResetting the units Communication Error messageGetting the current status Electricity failure I C C S U N k e yb o a r d e m u l a t i o n SUN key Combo key S B / S U N C o m b o k e ysVGA Te c h n i c a l Specification sWeee compliance Safety201204196