Q-Logic QLA12160 manual Installation in the Computer

Page 11

2 – Hardware Installation

Installation in the Computer

light to the J9 jumper block on the QLA12160 board (pins 1 and 4 are positive). If your boot drive is an integrated device electronics (IDE) drive or connected to a different adapter, you can connect an LED to the QLA12160 board jumper blocks to show activity of devices connected to your QLA12160 board.

2.6

Installation in the Computer

If you changed the termination on the QLA12160 board, double-check the new setting prior to installation.

Perform the following steps to install the QLA12160 board in your PC:

1.Check the motherboard and make any configuration changes necessary to accommodate the QLA12160 board.

The QLA12160 board is self-configuring; however, some motherboards require manual configuration. For example, some systems have a PCI Device Configuration menu in the motherboard setup BIOS where you must enable host adapter boards, bus master slots, and interrupt request (IRQ) levels. If your motherboard supports triggering, use level triggering for the QLA12160 board. See the documentation supplied with your computer, or contact your computer dealer to determine whether or not your motherboard requires configuration.

2.Power down the peripherals, then the computer.

3.Remove the computer cover and save the screws.

4.Choose any PCI bus slot that supports bus mastering. Most motherboards automatically assign an IRQ level and interrupt line. If your motherboard does not, you must assign the IRQ level and use interrupt line A for this slot.

NOTE:

Some motherboards have two kinds of PCI bus slots: master and slave. The QLA12160 board must be in a PCI bus master slot. (Some motherboards share PCI bus master slots with onboard devices; QLA12160 boards do not work in shared slots.)

If your board is labeled QLA12160/66, it can run in a 66-MHz PCI slot.

QLogic recommends installing the QLA12160/33 in a

33-MHz PCI slot and the QLA12160/66 in a 66-MHz PCI slot.

Installing a QLA12160/33 adapter in a 66-MHz PCI slot forces the entire PCI bus to 33 MHz.

Installing a QLA12160/66 in a 33-MHz slot does not provide the board with the performance benefits of a 66-MHz PCI bus.

BC8151101-00 C

2-3

Image 11
Contents Hardware Installation Guide for QLA12160 Board QLogic Corporation Table of Contents Figures Scsi Data Transfer Rates IntroductionProduct Description Features Mixed Peripheral Support Features What You Need for Installation Hardware InstallationPreinstallation Procedures Installing the Device Activity Light Setting the Scsi TerminationScsi Termination Power Installation in the Computer Number Installation Help Installation Help System Configuration Problem Checklist TroubleshootingProblems After Installation Hardware Problem ChecklistMaximum Cable Length Scsi Problem ChecklistIntroduction Configuration SettingsTable A-1. Host Adapter Settings Host Adapter SettingsTable A-2. Scsi Device Settings Scsi Device SettingsEnable Device Table A-3. Scsi Bus Settings Scsi Bus SettingsTable A-4. QLA12160 Ports Scsi terminationSelectable Boot Settings Autoconfigure Scsi DevicesScan Scsi Bus Restore Default SettingsUsing SCSI-1 Devices Raw Nvram DataFast!UTIL Using SCSI-1 Devices Using SCSI-1 Devices Fast!UTIL DC8151101-00 C Termination Jumpers for the QLA12160 Scsi TerminationFigure B-1. QLA12160 Jumper Termination Table C-1. QLA12160 Board Operating Environment SpecificationsTable C-2. QLA12160 Board Specifications Specifications