Page 49

 

NE-4100 Series User’s Manual

Web Console Configuration

 

 

 

 

 

Inactivity time is ONLY active when “TCP connection on” is set to “Any character.”

Delimiter 1

Setting

Factory Default

Necessity

00 to FF

“0” for None

Optional

 

 

 

Delimiter 2

 

 

Setting

Factory Default

Necessity

00 to FF

“0” for None

Optional

 

 

 

Once the NE-4100 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it out the NE-4100’s Ethernet port.

Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1K, the NE-4100 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly.

Force transmit

Setting

Factory Default

Necessity

0 to 65535 ms

0 ms

Optional

0: Disable the force transmit timeout.

1 to 65535: Forces the NE-4100’s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame.

This parameter defines the interval during which NE-4100 fetches the serial data from its internal buffer. If there is incoming data through the serial port, NE-4100 stores data in the internal buffer. NE-4100 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the force transmit time interval reaches the time specified as Force Transmit timeout.

Optimal force transmit timeout differs according to your application, but it must be at least as large as one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no for parity. In this case, the total number of bits required to send a character is 10 bits, and the time required to transfer one character is

( 10 bits / 1200 bits/s ) * 1000 = 8.3 ms.

Therefore, you should set Force Transmit timeout to be larger than 8.3 ms. Force Transmit timeout is specified in milliseconds and must be larger than 10 ms.

If the user wants to send a series of characters in a packet, the serial device attached to NE-4100 should send characters without time delay larger than Force Transmit timeout between characters and the total length of data must be smaller than or equal to NE-4100’s internal buffer size. The serial communication buffer size of NE-4100 is 1 Kbyte per port.

Destination IP address 1/2/3/4

Setting

Factory Default

Necessity

IP address or domain name

None

Required

(e.g., 192.168.1.1)

 

 

Allows NE-4100 to connect actively to the remote host whose address is set by this parameter.

Up to 4 connections can be established between NE-4100 and hosts. The connection speed or throughput may be low if one of the four connections is slow. In this case, the other 3 connections will be delayed while waiting for the slowest connection to finish transmitting or receiving.

6-14

Image 49
Contents Sixth Edition, April NE-4100 Series User’s ManualCopyright Notice Table of Contents Chapter Configuring Windows Administrator Introduction Product Features Package ChecklistOverview Product Specifications NE-4120 Series/NE-4120-ST Panel Layout and Pin AssignmentsPanel Layouts NE-4100T/NE-4100-STNE-4100T NE-4100-STRXD1 Pin AssignmentsNE-4100-ST LED Indicators Block DiagramLED Name LED Color LED Function NE-4110S NE-4110 Series/NE-4110-STNE-4110A NE-4110-ST evaluation board for NE-4110 SeriesSerial Header Pinouts J1 for NE-4110A Serial Header Pinouts J1 for NE-4110SEthernet Port Pinouts for NE-4110S/A DIO and LED Header Pinouts J2 for NE-4110S/ANE-4110S Block Diagram Block DiagramsNE-4110A Block Diagram NE-4110-ST LED Indicators Top Panel of NE-4120S NE-4120 Series/NE-4120-STTop Panel of NE-4120A NE-4120-ST evaluation board for NE-4120 SeriesSerial Header Pinouts J1 for NE-4120A Serial Header Pinouts J1 for NE-4120SNE-4120A Block Diagram NE-4120S Block DiagramNE-4120-ST LED Indicators Getting Started Attaching NE-4100T to the Evaluation Board Wiring RequirementsAttaching NE-4120 Series to the Evaluation Board Attaching NE-4110 Series to the Evaluation BoardCircuit Pad for External Connection Connecting to the Network Connecting the PowerConnecting to a Serial Device DI/O SettingsDigital Output LED Circuit Design JP2 Selecting the InterfaceChoosing the Proper Operation Mode TCP Server Mode UDP Mode TCP Client ModeReal COM Mode ARP Initial IP Address ConfigurationNE-4100 Series Administration Suite Factory Default IP AddressDefault IP address Initializing NE-4100 Series Module’s IP AddressTelnet Console Page Serial Console 19200, n, 8 Web Console Configuration Opening Your Browser Server name Basic SettingsTime zone Time server Setting Factory Default NecessityMethod Function Definition Network SettingsIP Address Setting Factory Default Necessity None Optional Setting Factory Default Necessity 255.255.255.0 RequiredIP configuration GatewayContact Community nameLocation Auto report to IPSerial Settings TCP Server Mode Operating SettingsMax. connection Max connectionMax connection 2 to DelimiterSetting Factory Default Necessity 4001 Required Real COM ModeCommand port Setting Factory Default Necessity 966 OptionalNE-4100 Series User’s Manual Web Console Configuration TCP Client Mode Destination IP address 1/2/3/4 TCP connection on UDP ModeLocal Listen port # Hosts on a given subnet can access the NE-4100 Accessible IP Settings# Any host can access the NE-4100 Allowable Hosts Input formatMail and Snmp Trap Auto Warning SettingsEvent Type DIO Monitor Digital IOLoad Factory Defaults Change PasswordSave/Restart Monitor Port Monitor COM Mapping Configuring Windows AdministratorInstalling Network Enabler Administrator NE-4100 Series User’s Manual Web Console Configuration Broadcast Search Starting the ConfigurationNE-4100 Series User’s Manual Web Console Configuration Unlock Password Protection Unlock LockBlank FixedConfiguring NE-4100 Upgrading the Firmware Export/Import Monitor Select Add Target NE-4100 Series User’s Manual Web Console Configuration NE-4100 Series User’s Manual Web Console Configuration Port Monitor On-line COM Mapping COM MappingSelect COM Setting to modify COM No., default setting, etc NE-4100 Series User’s Manual Web Console Configuration Off-line COM Mapping SW Reset Function NE-4100 Series User’s Manual SW Reset Function Well Known Port Numbers TCP Socket Application ServiceNE-4100 Series User’s Manual Well Known Port Numbers UDP Socket Application ServiceNeci Library Command Packet Format Length Bytes Header Data DIO CommandsACK Packet Format Length Bytes Header Data Data Structure DefinitionWriting a Single DIO Parameters Command Code Usage Reading Single DIO ParametersReading Multiple DIOs NE-4100 Series User’s ManualDIO CommandsWriting Multiple DIOs Snmp Agent with MIB II & RS-232 Like Group Address Translation MIB System MIB Interfaces MIBService Information Following services are provided Moxa Internet ServicesMoxa Product & NE-4100T Problem Report FormSerial Number Product Return Procedure